Tamper-resistant GFCI duplex receptacle type 5-20RA, which can take 5-15 and 5-20 grounding plugs and 1-15 non-grounding plugs. These versions of the 5-15R or 5-20R receptacle are residual-current devices, and have "Test" and "Reset" buttons (and sometimes an indicator light which may be normally on or normally off per the vendor's design). In ...
A Leviton GFCI "Decora" socket in a North American kitchen. Local electrical code requires tamper-resistant socket in homes, and requires a GFCI for socket within 1 metre of a sink. The T-slot indicates this device is rated 20 A and can take either a NEMA 5-15 or a NEMA 5-20 plug, though the latter type is rare on household appliances.
However a 10 A 5-pin plug cannot fit a 32 A 5-pin socket, as the plugs are in different groups and not only are their diameters different, but the position of the conductors also varies by a few degrees (for example the group 7/8 32 A plug has its L and N pins at 9 o'clock and 3 o'clock, while the group 1/2 20 A plug has its L and N pins at 10 ...
Tamper-resistant sockets may be required in new residential construction, with shutters on the power blade sockets to prevent contact by objects inserted into the socket. [ 48 ] In stage lighting , this connector is sometimes known as PBG for Parallel Blade with Ground , Edison or Hubbell , the name of a common manufacturer.
Corrected image size. 19:03, 20 June 2020: 5,104 × 3,082 (1.44 MB) JGrimm: Brazil adopted the "NBR 14136" standard, based on IEC 60906-1. South Africa implemented the "SANS 164-5" that also relies on 60906-1, although types D and M are still supported. Both countries are almost a decade with full enforcement of the new standards.
Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor use, but type 5 is not. A NEMA enclosure rating does not mean that it also meets the same UL enclosure rating. [2]
This is called a "false" or "bootleg" ground and is a serious safety hazard [10]: 49 often undetected by common receptacle testers. [1]: 48–49 Replacing the obsolete receptacle with a GFCI receptacle is the safest alternative, other than installing a new cable from the main circuit breaker panel.
Hubbell had been one of the first to manufacture flush toggle switches for alternating current only. The first Safety Receptacle was designed and produced as were the original "grounding only" devices which helped to set the standards for the industry. And while Hubbell was busy on land, the company found new opportunities at sea.