Common absorption refrigerators use a refrigerant with a very low boiling point (less than −18 °C (0 °F)) just like compressor refrigerators.Compression refrigerators typically use an HCFC or HFC, while absorption refrigerators typically use ammonia or water and need at least a second fluid able to absorb the coolant, the absorbent, respectively water (for ammonia) or brine (for water).
An important parameter in wet scrubbing systems is the rate of liquid flow. It is common in wet scrubber terminology to express the liquid flow as a function of the gas flow rate that is being treated. This is commonly called the liquid-to-gas ratio (L/G ratio) and uses the units of gallons per 1,000 actual cubic feet or litres per cubic metre ...
Typical vapor–liquid separator In chemical engineering , the Souders–Brown equation (named after Mott Souders and George Granger Brown [ 1 ] [ 2 ] ) has been a tool for obtaining the maximum allowable vapor velocity in vapor–liquid separation vessels (variously called flash drums , knockout drums , knockout pots , compressor suction drums ...
Vertical separators are generally used when the gas-liquid ratio is high or gas volumes are high. Horizontal separators are used where large volumes of liquid are involved. [5] A vapor-liquid separator may operate as a 3-phase separator, with two immiscible liquid phases of different densities. For example natural gas (vapor), water and oil ...
The typical basic scheme for supersonic separation is an arrangement where the feed gas is pre-cooled in a heat exchanger by the dry stream of the separator unit. The liquid phase from the supersonic separator goes into a 2-phase or 3-phase separator, where the slip gas is separated from water and/or from liquid hydrocarbons. The gaseous phase ...
Gas separation can refer to any of a number of techniques used to separate gases, either to give multiple products or to purify a single product.
In the classic dilution refrigerator (known as a wet dilution refrigerator), the 3 He is precooled and purified by liquid nitrogen at 77 K and a 4 He bath at 4.2 K. Next, the 3 He enters a vacuum chamber where it is further cooled to a temperature of 1.2–1.5 K by the 1 K bath , a vacuum-pumped 4 He bath (as decreasing the pressure of the ...
The gas–liquid separation section of the separator is determined by the maximum removal droplet size using the Souders–Brown equation with an appropriate K factor. The oil-water separation section is held for a retention time that is provided by laboratory test data, pilot plant operating procedure, or operating experience.