enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Vibrating-sample magnetometer - Wikipedia

    en.wikipedia.org/wiki/Vibrating-sample_magnetometer

    A vibrating-sample magnetometer (VSM) (also referred to as a Foner magnetometer) is a scientific instrument that measures magnetic properties based on Faraday’s Law of Induction. Simon Foner at MIT Lincoln Laboratory invented VSM in 1955 and reported it in 1959. [ 1 ]

  3. Magnetometer - Wikipedia

    en.wikipedia.org/wiki/Magnetometer

    The first magnetometer capable of measuring the absolute magnetic intensity at a point in space was invented by Carl Friedrich Gauss in 1833 and notable developments in the 19th century included the Hall effect, which is still widely used. Magnetometers are widely used for measuring the Earth's magnetic field, in geophysical surveys, to detect ...

  4. SQUID - Wikipedia

    en.wikipedia.org/wiki/SQUID

    A SQUID (superconducting quantum interference device) is a very sensitive magnetometer used to measure extremely weak magnetic fields, based on superconducting loops containing Josephson junctions. SQUIDs are sensitive enough to measure fields as low as 5×10 −18 T with a few days of averaged measurements. [ 1 ]

  5. Scanning SQUID microscopy - Wikipedia

    en.wikipedia.org/wiki/Scanning_SQUID_microscopy

    To use the DC SQUID to measure standard magnetic fields, one must either count the number of oscillations in the voltage as the field is changed, which is very difficult in practice, or use a separate DC bias magnetic field parallel to the device to maintain a constant voltage and consequently constant magnetic flux through the loop.

  6. Magnetic immunoassay - Wikipedia

    en.wikipedia.org/wiki/Magnetic_immunoassay

    Functioning in a way similar to that of an ELISA or Western Blot, a two-antibody binding process is used to determine concentrations of analytes. MIA uses antibodies that are coating a magnetic bead. These anti-bodies directly bind to the desired pathogen or molecule and the magnetic signal given off the bound beads is read using a magnetometer.

  7. Nuclear magnetic resonance spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Nuclear_magnetic_resonance...

    A 900 MHz NMR instrument with a 21.1 T magnet at HWB-NMR, Birmingham, UK Nuclear magnetic resonance spectroscopy, most commonly known as NMR spectroscopy or magnetic resonance spectroscopy (MRS), is a spectroscopic technique based on re-orientation of atomic nuclei with non-zero nuclear spins in an external magnetic field.

  8. Magnetic anomaly - Wikipedia

    en.wikipedia.org/wiki/Magnetic_anomaly

    Optically pumped magnetometers, which use alkali gases (most commonly rubidium and caesium) have high sample rates and sensitivities of 0.001 nT or less, but are more expensive than the other types of magnetometers. They are used on satellites and in most aeromagnetic surveys. [3]: 78–79

  9. Mu-metal - Wikipedia

    en.wikipedia.org/wiki/Mu-metal

    Mu-metal shields for cathode-ray tubes (CRTs) used in oscilloscopes, from a 1945 electronics magazine. Mu-metal is a soft magnetic alloy with exceptionally high magnetic permeability. The high permeability of mu-metal provides a low reluctance path for magnetic flux, leading to its use in magnetic shields against static or slowly varying ...