enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling tower - Wikipedia

    en.wikipedia.org/wiki/Cooling_tower

    A typical evaporative, forced draft open-loop cooling tower rejecting heat from the condenser water loop of an industrial chiller unit Natural draft wet cooling hyperboloid towers at Didcot Power Station (UK) Forced draft wet cooling towers (height: 34 meters) and natural draft wet cooling tower (height: 122 meters) in Westphalia, Germany Natural draft wet cooling tower in Dresden (Germany)

  3. File:Crossflow diagram.svg - Wikipedia

    en.wikipedia.org/wiki/File:Crossflow_diagram.svg

    This diagram is a retouched picture, ... Induced draft crossflow type cooling tower. {{fr}} schéma transversal d'une tour de refroidissement ...

  4. Draft (boiler) - Wikipedia

    en.wikipedia.org/wiki/Draft_(boiler)

    Normally it is done with the help of a forced draft fan. [2] Induced draft: When air or flue gases flow under the effect of a gradually decreasing pressure below atmospheric pressure. In this case, the system is said to operate under induced draft. The stacks (or chimneys) provide sufficient natural draft to meet the low draft loss needs.

  5. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The draft (draught in British English) flow rate induced by the stack effect can be calculated with the equation presented below. [12] [13] The equation applies only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building and A is the flow area of the openings.

  6. Water cooling - Wikipedia

    en.wikipedia.org/wiki/Water_cooling

    Large mechanical induced-draft or forced-draft cooling towers in industrial plants continuously circulate cooling water through heat exchangers and other equipment where the water absorbs heat. That heat is then rejected to the atmosphere by the evaporation of some of the water in cooling towers where upflowing air contacts the downflowing water.

  7. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The impacts include thermal pollution and killing large numbers of fish and other aquatic species at cooling water intakes. [17] [18] A Marley mechanical induced draft cooling tower. The heat absorbed by the circulating cooling water in the condenser tubes must also be removed to maintain the ability of the water to cool as it circulates.

  8. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. The condensing side of the chiller can be either air or water cooled. Even when liquid cooled, the chiller is often cooled by an induced or forced draft cooling tower ...

  9. Circulating water plant - Wikipedia

    en.wikipedia.org/wiki/Circulating_Water_Plant

    In the present era, mechanical induced draft–type cooling towers are employed in cooling of water. Performance testing of cooling towers (both IDCT and NDCT) shall be carried out as per ATC-105 [4] at a time when the atmospheric conditions are within the permissible limits of deviation from the design conditions.