Search results
Results from the WOW.Com Content Network
The respective tables of data were generally developed by using the more complex transfer function method to determine the various cooling loads for different types of heating. [ 2 ] [ 3 ] The results gained by doing so are then normalized for each type of heat gain used for the tables, CLTD, CLF, and SCL.
Depiction of New York World Building fire in New York City in 1882. Building codes in the United States are a collection of regulations and laws adopted by state and local jurisdictions that set “minimum requirements for how structural systems, plumbing, heating, ventilation, and air conditioning (), natural gas systems and other aspects of residential and commercial buildings should be ...
It is defined as per unit of skin surface area which equals to 58.2 W/m 2 (18.4 Btu/h·ft 2). This is the energy produced from a unit skin surface area of an average person seated at rest. [1] ANSI/ASHRAE Standard 55 provides a table of metabolic rate of different continuous activities
Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.
The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h. The air exchange rate is also known as air changes per hour (ACH).
ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...
The 1989 ASHRAE standard (Standard 62–89) states that appropriate ventilation guidelines are 20 CFM (9.2 L/s) per person in an office building, and 15 CFM (7.1 L/s) per person for schools, while 2004 Standard 62.1-2004 has lower recommendations again (see tables below). ANSI/ASHRAE (Standard 62–89) speculated that "comfort (odor) criteria ...
ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]