enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Heating degree day - Wikipedia

    en.wikipedia.org/wiki/Heating_degree_day

    Likewise, a similar home in Miami, Florida, whose heating degree days for the heating season is 500, would require around one tenth of the energy required to heat the house in New York City. [7] However, this is a theoretical approach as the level of insulation of a building affects the demand for heating. For example, temperatures often drop ...

  4. Balance point temperature - Wikipedia

    en.wikipedia.org/wiki/Balance_point_temperature

    The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.

  5. Degree day - Wikipedia

    en.wikipedia.org/wiki/Degree_day

    Degree days are a useful metric for estimating energy consumption required for household heating and cooling, and in this context are formally referred to as heating degree days. Since the escape or ingress of heat due to conduction is proportional to the difference between the indoor and outdoor temperature, the amount of energy needed to ...

  6. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    Heating seasonal performance factor (HSPF) is a term used in the heating and cooling industry. HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU ...

  7. Pinch analysis - Wikipedia

    en.wikipedia.org/wiki/Pinch_analysis

    Classical pinch-analysis primarily calculates the energy costs for the heating and cooling utility. At the pinch point, where the hot and cold streams are the most constrained, large heat exchangers are required to transfer heat between the hot and cold streams. Large heat exchangers entail high investment costs.

  8. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  9. ASHRAE 90.1 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_90.1

    ANSI/ASHRAE/IES Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings is an American National Standards Institute (ANSI) standard published by ASHRAE and jointly sponsored by the Illuminating Engineering Society (IES) that provides minimum requirements for energy efficient designs for buildings except for low-rise residential buildings (i.e. single-family homes ...