enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.

  3. Fire damper - Wikipedia

    en.wikipedia.org/wiki/Fire_damper

    Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...

  4. Fire-resistance rating - Wikipedia

    en.wikipedia.org/wiki/Fire-resistance_rating

    The length of time required for a penetrant or sample on average to exceed a specified average heat rise above ambient at any single location determines the duration for the FT Rating (Fire and Temperature). If a hose-stream test is passed afterwards, the rating can then be expressed as an FTH Rating (Fire, Temperature and Hose-stream). The ...

  5. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Smaller components such as fire dampers, fire doors, etc., follow suit in the main intentions of the basic standard for walls and floors. Fire testing involves live fire exposures upwards of 1100 °C, depending on the fire-resistance rating and duration one is after.

  6. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC TS 60680 Test methods of plasma equipment for electroheat and electrochemical applications; IEC 60682 Standard method of measuring the pinch temperature of quartz-tungsten-halogen lamps; IEC 60683 Industrial electroheating equipmentTest methods for submerged-arc furnaces; IEC 60684 Flexible insulating sleeving

  7. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity, and provides for automatic control of equipment, and ...

  8. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    A fire damper's most important feature is a mechanical fusible link which is a piece of metal that will melt or break at a specified temperature. This allows the damper to close (either from gravity or spring power), effectively sealing the duct, containing the fire, and blocking the necessary air to burn.

  9. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    The fire and gas detection system comprises local sensors to detect the presence of gas, smoke or fire. These initiate alarms in the control room. Simultaneous detection of multiple sensors initiates action to start firewater pumps and close fire dampers in enclosed spaces. The petrochemical plant may have several levels of shutdown.