enow.com Web Search

  1. Ads

    related to: boiler steam treatment

Search results

  1. Results from the WOW.Com Content Network
  2. Boiler water treatment - Wikipedia

    en.wikipedia.org/wiki/Boiler_water

    Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam.The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.

  3. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.

  4. Boiler blowdown - Wikipedia

    en.wikipedia.org/wiki/Boiler_blowdown

    A steam boiler evaporates liquid water to form steam, or gaseous water, and requires frequent replenishment of boiler feedwater for the continuous production of steam required by most boiler applications. Water is a capable solvent, and will dissolve small amounts of solids from piping and containers including the boiler.

  5. Boiler (power generation) - Wikipedia

    en.wikipedia.org/wiki/Boiler_(power_generation)

    A boiler or steam generator is a device used to create steam by applying heat energy to water. Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (7–2,000 kPa or 1–290 psi) but, at pressures above this, it is more usual to speak of a ...

  6. Industrial water treatment - Wikipedia

    en.wikipedia.org/wiki/Industrial_water_treatment

    Two of the main processes of industrial water treatment are boiler water treatment and cooling water treatment. A large amount of proper water treatment can lead to the reaction of solids and bacteria within pipe work and boiler housing. Steam boilers can suffer from scale or corrosion when left untreated. Scale deposits can lead to weak and ...

  7. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    In general, valves nearest to the boiler should vent the slowest, and valves furthest from the boiler should vent the fastest. [citation needed] Ideally, steam should reach each valve and close each and every valve at the same time, so that the system can work at maximal efficiency; this condition is known as a "balanced" system. [citation needed]

  8. Condensate polisher - Wikipedia

    en.wikipedia.org/wiki/Condensate_polisher

    During the process of steam generation in power plants, the steam cools and condensate forms. The condensate is collected and then recycled as boiler feedwater. Prior to re-use, the condensate must be purified or "polished", to remove impurities (predominantly silicon oxides and sodium hydroxide) which have the potential to cause damage to the ...

  9. Steam and water analysis system - Wikipedia

    en.wikipedia.org/wiki/Steam_and_water_analysis...

    Steam and water analysis system (SWAS) [1] is a system dedicated to the analysis of steam or water.In power stations, it is usually used to analyze boiler steam and water to ensure the water used to generate electricity is clean from impurities which can cause corrosion to any metallic surface, such as in boiler and turbine.

  1. Ads

    related to: boiler steam treatment