enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Scintillation counter - Wikipedia

    en.wikipedia.org/wiki/Scintillation_counter

    Apparatus with a scintillating crystal, photomultiplier, and data acquisition components. animation of radiation scintillation counter using a photomultiplier tube. When an ionizing particle passes into the scintillator material, atoms are excited along a track. For charged particles the track is the path of the particle itself.

  3. Radioanalytical chemistry - Wikipedia

    en.wikipedia.org/wiki/Radioanalytical_chemistry

    Sample loss at trace levels may be due to adhesion to container walls and filter surface sites by ionic or electrostatic adsorption, as well as metal foils and glass slides. Sample loss is an ever present concern, especially at the beginning of the analysis path where sequential steps may compound these losses.

  4. Liquid scintillation counting - Wikipedia

    en.wikipedia.org/wiki/Liquid_scintillation_counting

    Liquid scintillation counter. Samples are dissolved or suspended in a "cocktail" containing a solvent (historically aromatic organics such as xylene or toluene, but more recently less hazardous solvents are used), typically some form of a surfactant, and "fluors" or scintillators which produce the light measured by the detector.

  5. Alpha-particle spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Alpha-particle_spectroscopy

    The alpha spectra obtained by liquid scintillation counting are broaden because of the two main intrinsic limitations of the LSC method: (1) because the random quenching reduces the number of photons emitted per radioactive decay, and (2) because the emitted photons can be absorbed by cloudy or coloured samples (Lambert-Beer law).

  6. Kamioka Liquid Scintillator Antineutrino Detector - Wikipedia

    en.wikipedia.org/wiki/Kamioka_Liquid_Scintillat...

    First results were reported using only 145 days of data. [5] Without neutrino oscillation, 86.8 ± 5.6 events were expected, however, only 54 events were observed. KamLAND confirmed this result with a 515-day data sample, [6] 365.2 events were predicted in the absence of oscillation, and 258 events were observed. These results established ...

  7. Scintillation proximity assay - Wikipedia

    en.wikipedia.org/wiki/Scintillation_proximity_assay

    The SPA technique is dependent on the energy conversion of radioactive decay, which releases light photons which can be detected via the use of some devices such as the photomultiplier tubes of scintillation counters or CCD imagers. This is a very popular technique in practices that require detecting and quantifying radioactivity. [1]

  8. Radioactivity in the life sciences - Wikipedia

    en.wikipedia.org/wiki/Radioactivity_in_the_life...

    A good example of the difference in energy of the various radionuclei is the detection window ranges used to detect them, which are generally proportional to the energy of the emission, but vary from machine to machine: in a Perkin elmer TriLux Beta scintillation counter , the hydrogen-3 energy range window is between channel 5–360; carbon-14 ...

  9. Gamma spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Gamma_spectroscopy

    The output from the scintillation counter goes to a Multichannel Analyzer which processes and formats the data. The main components of a gamma spectrometer are the energy-sensitive radiation detector and the electronic devices that analyse the detector output signals, such as a pulse sorter (i.e., multichannel analyzer ).