enow.com Web Search

  1. Ads

    related to: maximum suction pressure of pump temperature sensor

Search results

  1. Results from the WOW.Com Content Network
  2. Thermodynamic pump testing - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_pump_testing

    Thermodynamic pump testing is a form of pump testing where only the temperature rise, power consumed, and differential pressure need to be measured to find the efficiency of a pump. These measurements are typically made with insertion temperature probes and pressure probes fitted to tapping points on the pump's inlet and outlet. [ 1 ]

  3. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  4. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    The refrigerant is compressed by the compressor to a high-pressure and high-temperature gaseous state. The high-pressure and high-temperature gas then enters the condenser. The condenser cools the high-pressure and high-temperature gas allowing it to condense to a high-pressure liquid by transferring heat to a lower temperature medium, usually ...

  5. Suction pressure - Wikipedia

    en.wikipedia.org/wiki/Suction_pressure

    In refrigeration and air conditioning systems, the suction pressure' (also called the low-side pressure) is the intake pressure generated by the system compressor while operating. The suction pressure, along with the suction temperature the wet bulb temperature of the discharge air are used to determine the correct refrigerant charge in a system.

  6. Turbomolecular pump - Wikipedia

    en.wikipedia.org/wiki/Turbomolecular_pump

    Since the mean free path is inversely proportional to pressure, a turbopump will pump when the exhaust pressure is less than about 10 Pa (0.10 mbar) where the mean free path is about 0.7 mm. Most turbopumps have a Holweck pump (or molecular drag pump) as their last stage to increase the maximum backing pressure (exhaust pressure) to about 1 ...

  7. Metering pump - Wikipedia

    en.wikipedia.org/wiki/Metering_pump

    An engineer, designer, or user should ensure that the pressure and temperature ratings and wetted pump materials are compatible for the application and the type of liquid being pumped. Most metering pumps have a pump head and a motor. The liquid being pumped goes through the pump head, entering through an inlet line and leaving through an ...

  8. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    In many late model automobiles, a Mass Airflow (MAF) sensor is used to accurately determine the mass flow rate of intake air used in the internal combustion engine. Many such mass flow sensors use a heated element and a downstream temperature sensor to indicate the air flowrate. Other sensors use a spring-loaded vane.

  9. Trace heating - Wikipedia

    en.wikipedia.org/wiki/Trace_heating

    Normally, a thermostat is used to energise when it measures temperature falling below a set temperature value - usually between 3 °C and 5 °C and often referred to as the 'setpoint'. The thermostat will de-energise the trace heating when it measures temperature rising past another set temperature value - usually 2 °C higher than the setpoint ...

  1. Ads

    related to: maximum suction pressure of pump temperature sensor