  2. X-ray diffraction - Wikipedia

    en.wikipedia.org/wiki/X-ray_diffraction

    This is useful if the sample is too thick for X-rays to transmit through it. The diffracting planes in the crystal are determined by knowing that the normal to the diffracting plane bisects the angle between the incident beam and the diffracted beam. A Greninger chart can be used [30] to interpret the back reflection Laue photograph.

  3. Greninger chart - Wikipedia

    en.wikipedia.org/wiki/Greninger_chart

    The Greninger chart is a simple trigonometric tool to determine g and d for a fixed sample-to-film distance. (If one uses a 2-d detector the problem of determining g and d could be solved mathematically using the equations which generate the Greninger chart) A new chart must be generated for different sample to detector distances.

  4. X-ray diffraction computed tomography - Wikipedia

    en.wikipedia.org/wiki/X-ray_diffraction_computed...

    X-ray diffraction computed tomography, often abbreviated as XRD-CT, typically refers to the technique invented by Harding et al. [1] which assumes that the acquired data are powder diffraction data. For this reason, it has also been mentioned as powder diffraction computed tomography [ 7 ] and diffraction scattering computed tomography (DSCT ...

  5. Scherrer equation - Wikipedia

    en.wikipedia.org/wiki/Scherrer_Equation

    is the mean size of the ordered (crystalline) domains, which may be smaller or equal to the grain size, which may be smaller or equal to the particle size; is a dimensionless shape factor, with a value close to unity. The shape factor has a typical value of about 0.9, but varies with the actual shape of the crystallite;

  6. X-ray crystal truncation rod - Wikipedia

    en.wikipedia.org/wiki/X-ray_crystal_truncation_rod

    To obtain high-quality data in X-ray CTR measurements, it is desirable that the detected intensity be on the order of at least [citation needed]. To achieve this level of output, the X-ray source must typically be a synchrotron source. More traditional, inexpensive sources such as rotating anode sources provide 2-3 orders of magnitude less X ...

  7. Mass attenuation coefficient - Wikipedia

    en.wikipedia.org/wiki/Mass_attenuation_coefficient

    Mass attenuation coefficients of selected elements for X-ray photons with energies up to 250 keV. The mass attenuation coefficient, or mass narrow beam attenuation coefficient of a material is the attenuation coefficient normalized by the density of the material; that is, the attenuation per unit mass (rather than per unit of distance).

  8. R-factor (crystallography) - Wikipedia

    en.wikipedia.org/wiki/R-factor_(crystallography)

    In the Cambridge Structural Database of small-molecule structures, more than 95% of the 500,000+ crystals have an R-factor lower than 0.15, and 9.5% have an R-factor lower than 0.03. Crystallographers also use the Free R-Factor ( R F r e e {\displaystyle R_{Free}} ) [ 3 ] to assess possible overmodeling of the data.

  9. X-ray crystallography - Wikipedia

    en.wikipedia.org/wiki/X-ray_crystallography

    A powder X-ray diffractometer in motion. X-ray crystallography is the experimental science of determining the atomic and molecular structure of a crystal, in which the crystalline structure causes a beam of incident X-rays to diffract in specific directions.