Search results
Results from the WOW.Com Content Network
Steam and water analysis system (SWAS) [1] is a system dedicated to the analysis of steam or water.In power stations, it is usually used to analyze boiler steam and water to ensure the water used to generate electricity is clean from impurities which can cause corrosion to any metallic surface, such as in boiler and turbine.
The next step is to add dilute stannous chloride reagent, which has been freshly prepared from concentrated stannous chloride reagent and distilled water, to the mixture in the tube. This will produce a blue colour (due to the formation of molybdenum blue ) and the depth of the blue colour indicates the amount of phosphate in the boiler water.
Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam. The term may also be applied to raw water intended for use in boilers, treated boiler feedwater , steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.
Boiler feedwater is the water which is supplied to a boiler. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank.
A hydrostatic test is a way in which pressure vessels such as pipelines, plumbing, gas cylinders, boilers and fuel tanks can be tested for strength and leaks. The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection , and pressurization of the vessel to the specified ...
A steam boiler evaporates liquid water to form steam, or gaseous water, and requires frequent replenishment of boiler feedwater for the continuous production of steam required by most boiler applications. Water is a capable solvent, and will dissolve small amounts of solids from piping and containers including the boiler.
Social media site Bluesky has gained 1 million new users in the week since the U.S. election, as some X users look for an alternative platform to post their thoughts and engage with others online.
Oxidizable chemicals (such as reducing chemicals) introduced into a natural water will similarly initiate chemical reactions (such as shown above). Those chemical reactions create what is measured in the laboratory as COD. Both the BOD and COD tests are a measure of the relative oxygen-depletion effect of a waste contaminant.