enow.com Web Search

  1. Ads

    related to: roof decks on low-slope roofs must: side length feet and top view

Search results

  1. Results from the WOW.Com Content Network
  2. List of roof shapes - Wikipedia

    en.wikipedia.org/wiki/List_of_roof_shapes

    Mokoshi: A Japanese decorative pent roof; Pavilion roof : A low-pitched roof hipped equally on all sides and centered over a square or regular polygonal floor plan. [10] The sloping sides rise to a peak. For steep tower roof variants use Pyramid roof. Pyramid roof: A steep hip roof on a square building.

  3. Roof pitch - Wikipedia

    en.wikipedia.org/wiki/Roof_pitch

    A flat roof includes pitches as low as 1 ⁄ 2:12 to 2:12 (1 in 24 to 1 in 6), which are barely capable of properly shedding water. Such low-slope roofs (up to 4:12 (1 in 3)) require special materials and techniques to avoid leaks. [4] Conventional describes pitches from 4:12 (1 in 3) to 9:12 (3 in 4). [4]

  4. Flat roof - Wikipedia

    en.wikipedia.org/wiki/Flat_roof

    Flat roofs, or "low-slope" roofs, are also commonly found on commercial buildings throughout the world. The U.S.-based National Roofing Contractors Association defines a low-slope roof as having a slope of 3 in 12 (1:4) or less. [2] Flat roofs exist all over the world, and each area has its own tradition or preference for materials used.

  5. Purlin - Wikipedia

    en.wikipedia.org/wiki/Purlin

    A view of a roof using common purlin framing. The purlins are marked in red. This view is from the inside of the building, below the roof. The rafters are the beams of wood angled upward from the ground. They meet at the top of the gable at a ridge beam, which has extra bracing to attach it to the rafters.

  6. Domestic roof construction - Wikipedia

    en.wikipedia.org/wiki/Domestic_roof_construction

    A hot roof is a roof designed not to have any ventilation and has enough air-impermeable insulation in contact with the sheathing to prevent condensation [11] such as when spray foam insulation is applied directly to the under-side or top-side of the roof deck or in some cathedral ceilings. [12]

  7. Asphalt shingle - Wikipedia

    en.wikipedia.org/wiki/Asphalt_shingle

    Per 2003 International Building Code Sections 1507.2.1 and 1507.2.2, asphalt shingles shall only be used on roof slopes of two units vertical in 12 units horizontal (17% slope) or greater. Asphalt shingles shall be fastened to solidly sheathed decks. Shallower slopes require asphalt rolled roofing, or other roofing treatment.

  8. Covering (construction) - Wikipedia

    en.wikipedia.org/wiki/Covering_(construction)

    Bituminous shingles, also called "shingles," consist of a fiberglass or cellulose felt reinforcement and a mixture of bitumen and mineral granules. Various shapes are available: rounded, rectangular, and scale-like. These products are easily installed on low-slope roofs and lightweight structures due to their low weight.

  9. Asphalt roll roofing - Wikipedia

    en.wikipedia.org/wiki/Asphalt_roll_roofing

    Asphalt roll roofing or membrane is a roofing material commonly used for buildings that feature a low sloped roof pitch in North America. The material is based on the same materials used in asphalt shingles ; an organic felt or fiberglass mat, saturated with asphalt , and faced with granular stone aggregate.

  1. Ads

    related to: roof decks on low-slope roofs must: side length feet and top view