Search results
Results from the WOW.Com Content Network
In electrical engineering, an autotransformer is an electrical transformer with only one winding. The "auto" (Greek for "self") prefix refers to the single coil acting alone. In an autotransformer, portions of the same winding act as both the primary winding and secondary winding sides of the transformer. In contrast, an ordinary transformer ...
This basic principle explains the source of the destructive transient voltage in the Korndörfer motor starter apparatus. A further transient problem is that with a single coil construction and a star switch, the autotransformer acts as a step-up transformer during the <5 microsecond period at contact separation of the Star point switch.
Flyback converter's transformer works differently, like an inductor. In each cycle, the flyback converter's transformer first gets charged and then releases its energy to the load. Accordingly, the flyback converter's transformer air gap has two functions. It not only determines inductance but also stores energy.
A leakage transformer, also called a stray-field transformer, has a significantly higher leakage inductance than other transformers, sometimes increased by a magnetic bypass or shunt in its core between primary and secondary, which is sometimes adjustable with a set screw. This provides a transformer with an inherent current limitation due to ...
In practice, it is necessary to allow a small interval between powering the transformer one way and powering it the other: the “switches” are usually pairs of transistors (or similar devices), and were the two transistors in the pair to switch simultaneously there would be a risk of shorting out the power supply.
For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...
A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.
However, a transformer may include a tap changer on each winding if there are advantages to do so. For example, in power distribution networks, a large step-down transformer may have an off-load tap changer on the primary winding and an on load automatic tap changer on the secondary winding or windings. The high voltage tap is set to match long ...