Schematic view of a flow sensor. An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and ...
For the Parshall flume equation used to calculate the flow rate, both empirical values C and n are known constants (with various values for each Parshall flume size) leaving Ha (depth upstream) as the only variable needing to be measured. Likewise, in the energy conservation equation, y 1 (or the depth of flow) is needed.
Sonar flowmeters have the capacity of measuring the velocity of liquids or gases non-intrusively within the pipe and then leverage this velocity measurement into a flow rate by using the cross-sectional area of the pipe and the line pressure and temperature. The principle behind this flow measurement is the use of underwater acoustics.
There are 2 primary ultrasonic measurement technologies used in water metering: Doppler effect meters which utilize the Doppler Effect to determine the velocity of water passing through the meter. Transit Time meters which measure the amount of time required for the ultrasonic signal to pass between 2 or more fixed points inside the meter ...
Download QR code; Print/export Download as PDF; Printable version; In other projects Wikimedia Commons; ... Ultrasonic flow meter; Utility submeter; V. Vortex ...
The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .
Custody transfer of liquid flow measurement follow guidelines set by the ISO. By industrial consensus, liquid flow measurement is defined as having an overall uncertainty of ±0.25% or better. The overall uncertainty is derived from an appropriate statistical combination of the component uncertainties in the measurement system.
Note the location of critical flow, subcritical flow, and supercritical flow. The energy equation used for open channel flow computations is a simplification of the Bernoulli Equation (See Bernoulli Principle), which takes into account pressure head, elevation head, and velocity head. (Note, energy and head are synonymous in Fluid Dynamics.