enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Matched Z-transform method - Wikipedia

    en.wikipedia.org/wiki/Matched_Z-transform_method

    The matched Z-transform method, also called the polezero mapping [1] [2] or polezero matching method, [3] and abbreviated MPZ or MZT, [4] is a technique for converting a continuous-time filter design to a discrete-time filter (digital filter) design.

  3. Pole–zero plot - Wikipedia

    en.wikipedia.org/wiki/Polezero_plot

    A pole-zero plot shows the location in the complex plane of the poles and zeros of the transfer function of a dynamic system, such as a controller, compensator, sensor, equalizer, filter, or communications channel. By convention, the poles of the system are indicated in the plot by an X while the zeros are indicated by a circle or O.

  4. Z-transform - Wikipedia

    en.wikipedia.org/wiki/Z-transform

    In signal processing, this definition can be used to evaluate the Z-transform of the unit impulse response of a discrete-time causal system.. An important example of the unilateral Z-transform is the probability-generating function, where the component [] is the probability that a discrete random variable takes the value.

  5. Bilinear transform - Wikipedia

    en.wikipedia.org/wiki/Bilinear_transform

    The bilinear transform is a first-order Padé approximant of the natural logarithm function that is an exact mapping of the z-plane to the s-plane.When the Laplace transform is performed on a discrete-time signal (with each element of the discrete-time sequence attached to a correspondingly delayed unit impulse), the result is precisely the Z transform of the discrete-time sequence with the ...

  6. Pole–zero matching method - Wikipedia

    en.wikipedia.org/?title=Polezero_matching...

    Polezero matching method. Add languages. Add links. Article; Talk; English. Read; Edit; ... Text is available under the Creative Commons Attribution-ShareAlike 4.0 ...

  7. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    In many cases, the manipulated variable output by the PID controller is a dimensionless fraction between 0 and 100% of some maximum possible value, and the translation into real units (such as pumping rate or watts of heater power) is outside the PID controller.

  8. Root locus analysis - Wikipedia

    en.wikipedia.org/wiki/Root_locus_analysis

    that is, the sum of the angles from the open-loop zeros to the point (measured per zero w.r.t. a horizontal running through that zero) minus the angles from the open-loop poles to the point (measured per pole w.r.t. a horizontal running through that pole) has to be equal to , or 180 degrees.

  9. Transfer function - Wikipedia

    en.wikipedia.org/wiki/Transfer_function

    For a system to be stable, its transfer function must have no poles whose real parts are positive. If the transfer function is strictly stable, the real parts of all poles will be negative and the transient behavior will tend to zero in the limit of infinite time. The steady-state output will be: