enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Earth continuity test: this test is to make sure the earthing system is properly connected Live testing. Earth fault loop impedance testing: this test is to check that if a fault did occur, that the system meets requirements to cause a disconnection of the supply within the time limit specified by standards Insulation resistance testing

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    A ground fault (earth fault) is any failure that allows unintended connection of power circuit conductors with the earth. [citation needed] Such faults can cause objectionable circulating currents, or may energize the housings of equipment at a dangerous voltage. Some special power distribution systems may be designed to tolerate a single ...

  5. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Ground loop current induced by stray AC magnetic fields (B, green) Ground loop currents can be induced by stray AC magnetic fields [5] [7] (B, green) which are always present around AC electrical wiring. The ground loop constitutes a conductive wire loop which may have a large area of several square meters.

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The connection between neutral and earth allows any phase-to-earth fault to develop enough current flow to "trip" the circuit overcurrent protection device. In some jurisdictions, calculations are required to ensure the fault loop impedance is low enough so that fault current will trip the protection (In Australia, this is referred to in AS3000 ...

  7. Multifunction tester - Wikipedia

    en.wikipedia.org/wiki/Multifunction_tester

    Multifunction testers are able to perform continuity tests (or low ohms resistance tests) and insulation resistance tests (or high ohms resistance tests) and they may also be able to perform earth fault loop impedance tests, prospective short-circuit current tests, earth electrode tests and RCD tests.

  8. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Earth fault protection also requires current transformers and senses an imbalance in a three-phase circuit. Normally the three phase currents are in balance, i.e. roughly equal in magnitude. If one or two phases become connected to earth via a low impedance path, their magnitudes will increase dramatically, as will current imbalance.

  9. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    In an electrical grid, the short circuit ratio (or SCR) is the ratio of: the short circuit apparent power (SCMVA) in the case of a line-line-line-ground (3LG) fault at the location in the grid where some generator is connected, to: the power rating of the generator itself (GMW).