  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The resistance path is the total resistance back through the supply transformer; to measure this an engineer will use an "earth fault loop impedance meter". The application of a low voltage allows a small current to pass from the socket back through earth to the supply transformer and distribution board.

  3. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Ground loop current induced by stray AC magnetic fields (B, green) Ground loop currents can be induced by stray AC magnetic fields [5] [7] (B, green) which are always present around AC electrical wiring. The ground loop constitutes a conductive wire loop which may have a large area of several square meters.

  4. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Earth continuity test: this test is to make sure the earthing system is properly connected Live testing. Earth fault loop impedance testing: this test is to check that if a fault did occur, that the system meets requirements to cause a disconnection of the supply within the time limit specified by standards Insulation resistance testing

  5. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    A ground fault (earth fault) is any failure that allows unintended connection of power circuit conductors with the earth. [citation needed] Such faults can cause objectionable circulating currents, or may energize the housings of equipment at a dangerous voltage. Some special power distribution systems may be designed to tolerate a single ...

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The connection between neutral and earth allows any phase-to-earth fault to develop enough current flow to "trip" the circuit overcurrent protection device. In some jurisdictions, calculations are required to ensure the fault loop impedance is low enough so that fault current will trip the protection (In Australia, this is referred to in AS3000 ...

  7. Earth potential rise - Wikipedia

    en.wikipedia.org/wiki/Earth_potential_rise

    While the fault current from a distribution or transmission system can usually be calculated or estimated with precision, calculation of the earth grid resistance is more complicated. Difficulties in calculation arise from the extended and irregular shape of practical ground grids, and the varying resistivity of soil at different depths.

  8. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  9. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    There is no 'earth wire' between the two. The fault loop impedance is higher, and unless the electrode impedance is very low indeed, a TT installation should always have an RCD (GFCI) as its first isolator. The big advantage of the TT earthing system is the reduced conducted interference from other users' connected equipment.