enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Observational error - Wikipedia

    en.wikipedia.org/wiki/Observational_error

    If the next measurement is higher than the previous measurement as may occur if an instrument becomes warmer during the experiment then the measured quantity is variable and it is possible to detect a drift by checking the zero reading during the experiment as well as at the start of the experiment (indeed, the zero reading is a measurement of ...

  3. Measurement uncertainty - Wikipedia

    en.wikipedia.org/wiki/Measurement_uncertainty

    In metrology, measurement uncertainty is the expression of the statistical dispersion of the values attributed to a quantity measured on an interval or ratio scale.. All measurements are subject to uncertainty and a measurement result is complete only when it is accompanied by a statement of the associated uncertainty, such as the standard deviation.

  4. Instrument error - Wikipedia

    en.wikipedia.org/wiki/Instrument_error

    Measurement reading accuracy [ edit ] If the instrument has a needle which points to a scale graduated in steps of 0.1 units, then depending on the design of the instrument, it is usually possible to estimate tenths between the successive marks on the scale, so it should be possible to read off the result to an accuracy of about 0.01 units.

  5. Vernier scale - Wikipedia

    en.wikipedia.org/wiki/Vernier_scale

    The main scale reading is that to the left of the zero on the vernier scale. The vernier reading is found by locating the best aligned lines between the two scales. The 0.02 mm engraving indicates the caliper's readability and is the "vernier constant" for this scale.

  6. Micrometer (device) - Wikipedia

    en.wikipedia.org/wiki/Micrometer_(device)

    For example, a measurement of 5.783 millimetres would be obtained by reading 5.5 millimetres on the sleeve, and then adding 0.28 millimetre as determined by the thimble. The vernier would then be used to read the 0.003 (as shown in the image). Inch micrometers are read in a similar fashion.

  7. Accuracy and precision - Wikipedia

    en.wikipedia.org/wiki/Accuracy_and_precision

    Accuracy is also used as a statistical measure of how well a binary classification test correctly identifies or excludes a condition. That is, the accuracy is the proportion of correct predictions (both true positives and true negatives) among the total number of cases examined. [10]

  8. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    A vacuum gauge is used to measure pressures lower than the ambient atmospheric pressure, which is set as the zero point, in negative values (for instance, −1 bar or −760 mmHg equals total vacuum). Most gauges measure pressure relative to atmospheric pressure as the zero point, so this form of reading is simply referred to as "gauge pressure".

  9. Potentiometer (measuring instrument) - Wikipedia

    en.wikipedia.org/wiki/Potentiometer_(measuring...

    The galvanometer does not need to be calibrated, as its only function is to read zero or not zero. When measuring an unknown voltage and the galvanometer reads zero, no current is drawn from the unknown voltage and so the reading is independent of the source's internal resistance, as if by a voltmeter of infinite resistance.