Ads
related to: normal working load lifting system for water supply line shut off valve
Search results
Results from the WOW.Com Content Network
A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.
This load represents a force that is much less than that required to make the lifting equipment fail or yield. The WLL is calculated by dividing MBL by a safety factor (SF). An example of this would be a chain that has a MBL of 2000 lbf (8.89 kN ) would have a SWL or WLL of 400 lbf (1.78 kN) if a safety factor of 5 (5:1, 5 to 1, or 1/5) is used.
Larner–Johnson Valve: needle control valve often in large sizes used in water supply systems; Leaf valve: one-way valve consisting of a diagonal obstruction with an opening covered by a hinged flap; Line blind valve: a thin sheet oriented perpendicular to the pipe. The sheet has a solid end and a flow-through end; sliding it from one position ...
Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.
Hot load is the working load of the support in the “Hot” condition i.e. when the pipe has traveled from the cold condition to the hot or working condition. Normally MSS-SP58 specifies max Load Variation ( popularly called LV) as 25%. [4] Salient features- Allows movement in vertical direction; Load on pipe varies with movement; Used where
Gate valves are used to shut off the flow of liquids rather than for flow regulation, which is frequently done with a globe valve. When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low flow resistance. [1] The size of the open flow path generally varies in a nonlinear manner as the gate is moved.
Also, the tortuous S-shaped path the water is forced to follow offers a significant obstruction to the flow. For high pressure domestic water systems this does not matter, but for low pressure systems where flow rate is important, such as a shower fed by a storage tank, a "stop tap" or, in engineering terms, a "gate valve" is preferred.
A water supply network or water supply system is a system of engineered hydrologic and hydraulic components that provide water supply. A water supply system typically includes the following: A water supply system typically includes the following:
Ads