enow.com Web Search

  1. Ads

    related to: rtd vs thermocouple accuracy ratings chart pdf

Search results

  1. Results from the WOW.Com Content Network
  2. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements If a tolerance of 2 °C is acceptable and the highest level of repeatability is not required, a thermocouple will serve.

  3. Callendar–Van Dusen equation - Wikipedia

    en.wikipedia.org/wiki/Callendar–Van_Dusen_equation

    The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD). As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.

  4. List of temperature sensors - Wikipedia

    en.wikipedia.org/wiki/List_of_temperature_sensors

    The integrated circuit sensor may come in a variety of interfaces — analogue or digital; for digital, these could be Serial Peripheral Interface, SMBus/I 2 C or 1-Wire.. In OpenBSD, many of the I 2 C temperature sensors from the below list have been supported and are accessible through the generalised hardware sensors framework [3] since OpenBSD 3.9 (2006), [4] [5]: §6.1 which has also ...

  5. Thermocouple - Wikipedia

    en.wikipedia.org/wiki/Thermocouple

    A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction.A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.

  6. Temperature measurement - Wikipedia

    en.wikipedia.org/wiki/Temperature_measurement

    Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.

  7. File:Reference tables for the Platinel II thermocouple (IA ...

    en.wikipedia.org/wiki/File:Reference_tables_for...

    A comparison of the thermal emf of Platinel II with that of Chromel-Alumel is shown. The two thermocouples develop identical emfs at 32, 1300, and 2225 °F. Between 1000 and 2500 °F the maximum indicated difference is only 18 °F when the Chromel-Alumel reference table is used. Author: Olsen: Software used: Adobe Acrobat 9.0: Conversion program

  8. Signal conditioning - Wikipedia

    en.wikipedia.org/wiki/Signal_conditioning

    Some sensors require external voltage or current source of excitation, These sensors are called active sensors. (E.g. a temperature sensor like a thermistor & RTD, a pressure sensor (piezo-resistive and capacitive), etc.). The stability and precision of the excitation signal directly relates to the sensor accuracy and stability.

  9. Seebeck coefficient - Wikipedia

    en.wikipedia.org/wiki/Seebeck_coefficient

    In thermocouples the Seebeck effect is used to measure temperatures, and for accuracy it is desirable to use materials with a Seebeck coefficient that is stable over time. Physically, the magnitude and sign of the Seebeck coefficient can be approximately understood as being given by the entropy per unit charge carried by electrical currents in ...

  1. Ads

    related to: rtd vs thermocouple accuracy ratings chart pdf