enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Response factor - Wikipedia

    en.wikipedia.org/wiki/Response_factor

    In chromatography, the area of a peak is proportional to the number of moles (n) times some constant of proportionality (k), Area = k×n. The number of moles of compound is equal to the concentration (molarity, M) times the volume, n = MV. From these equations, the following derivation is made:

  3. Resolution (chromatography) - Wikipedia

    en.wikipedia.org/wiki/Resolution_(chromatography)

    Two resolved peaks in a chromatogram. The theoretical plate height is given by = where L is the column length and N the number of theoretical plates. [5] The relation between plate number and peak width at the base is given by = ().

  4. Fundamental resolution equation - Wikipedia

    en.wikipedia.org/.../Fundamental_Resolution_Equation

    The fundamental resolution equation is derived as follows: For two closely spaced peaks, ω 1 = ω 2, and σ 1 = σ 2. so R s = (t r2 - t r1)/ω 2 = (t r2 - t r1)/4σ 2. Where t r1 and t r2 are the retention times of two separate peaks. Since N = [(t r2)/σ 2] 2, then σ = t r2 / N 1/2. Using substitution, R s = N 1/2 [(t r2 - t r1)/4t r2] = (N ...

  5. Purnell equation - Wikipedia

    en.wikipedia.org/wiki/Purnell_equation

    The Purnell equation is an equation used in analytical chemistry to calculate the resolution R s between two peaks in a chromatogram. [1] [2] = (′ + ′) where R s is the resolution between the two peaks N 2 is the plate number of the second peak α is the separation factor between the two peaks k ' 2 is the retention factor of the second peak.

  6. PeakFit - Wikipedia

    en.wikipedia.org/wiki/PeakFit

    PeakFit is an automated nonlinear peak separation and analysis software package for scientists performing spectroscopy, chromatography and electrophoresis.. PeakFit automatically finds and fits up to 100 peaks to a data set, at a time, enabling users to characterize peaks and find the best equation that fits their data.

  7. Unresolved complex mixture - Wikipedia

    en.wikipedia.org/wiki/Unresolved_Complex_Mixture

    Gas chromatograms of mature oils have prominent n-alkane peaks which distract attention from the underlying unresolved complex mixture (UCM) of hydrocarbons often referred to as the ‘hump’. Processes such as weathering and biodegradation result in a relative enrichment of the UCM component by removal of resolved components and the creation ...

  8. Chromatography software - Wikipedia

    en.wikipedia.org/wiki/Chromatography_software

    Chromatography software is called also Chromatography Data System. [1] It is located in the data station of the modern liquid, gas or supercritical fluid chromatographic systems. This is a dedicated software connected to an hardware interface within the chromatographic system, which serves as a central hub for collecting, analyzing, and ...

  9. OpenChrom - Wikipedia

    en.wikipedia.org/wiki/OpenChrom

    OpenChrom is an open source software for the analysis and visualization of mass spectrometric and chromatographic data. [4] Its focus is to handle native data files from several mass spectrometry systems (e.g. GC/MS, LC/MS, Py-GC/MS, HPLC-MS), vendors like Agilent Technologies, Varian, Shimadzu, Thermo Fisher, PerkinElmer and others.

  1. Related searches gas chromatography peaks analysis calculator equation generator 2 8

    gas chromatography peaks analysis calculator equation generator 2 8 microlite