enow.com Web Search

  1. Ads

    related to: 3.5 inch plastic pipe home depot 1 inch conduit 12 2 romex with ground wire

Search results

  1. Results from the WOW.Com Content Network
  2. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  3. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    This does not include the uninsulated ground wire. For instance, if the cable lists "12-2 AWG", it means there are two insulated 12-gauge wires (a black and a white wire), plus a ground wire. If the label says "12-3", this cable has four conductors—three 12-gauge insulated wires and a bare copper ground wire. [5]

  4. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    FMT is a raceway, but not a conduit and is described in a separate NEC Article 360. It only comes in 1/2" & 3/4" trade sizes, whereas FMC is sized 1/2" ~ 4" trade sizes. NEC 360.2 describes it as: "A raceway that is circular in cross section, flexible, metallic and liquidtight without a nonmetallic jacket."

  5. HDPE pipe - Wikipedia

    en.wikipedia.org/wiki/HDPE_pipe

    HDPE pipe is a type of flexible plastic pipe used to transfer fluids and gases. It is often employed for replacing aging concrete or steel main pipelines . Constructed from the thermoplastic HDPE (high-density polyethylene ), it has low permeability and robust molecular bonding, making it suitable for high-pressure pipelines .

  6. Pipe insulation - Wikipedia

    en.wikipedia.org/wiki/Pipe_insulation

    For this reason, it is more common to use the thermal conductivity value when comparing the effectiveness of pipe insulation, and R-values of pipe insulation are not covered by the US FTC R-value rule Archived 2007-12-31 at the Wayback Machine. The thermal resistance of each insulation layer is calculated using the following equation:

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  8. Home Depot - Wikipedia

    en.wikipedia.org/wiki/Home_Depot

    This is an accepted version of this page This is the latest accepted revision, reviewed on 28 January 2025. American multinational home improvement supplies retailing company The Home Depot, Inc. An aerial view of a Home Depot in Onalaska, Wisconsin Company type Public Traded as NYSE: HD DJIA component S&P 100 component S&P 500 component Industry Retail (home improvement) Founded February 6 ...

  9. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  1. Ads

    related to: 3.5 inch plastic pipe home depot 1 inch conduit 12 2 romex with ground wire