enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Ankle–brachial pressure index - Wikipedia

    en.wikipedia.org/wiki/Ankle–brachial_pressure...

    A Doppler ultrasound blood flow detector, commonly called Doppler wand or Doppler probe, and a sphygmomanometer (blood pressure cuff) are usually needed. The blood pressure cuff is inflated proximal to the artery in question. Measured by the Doppler wand, the inflation continues until the pulse in the artery ceases.

  3. Doppler ultrasonography - Wikipedia

    en.wikipedia.org/wiki/Doppler_ultrasonography

    Absence of the portal system in a first trimester case associated with hygroma and aorto-umbilical fistula. (A): Transverse plane of the upper abdomen with color Doppler applied, showing umbilical cord insertion, stomach, the prominent hepatic artery and no afferent liver venous perfusion; (B): midsagittal plane reconstructed from a three-dimensional volume acquisition were the crown-rump ...

  4. Ultrasonography of chronic venous insufficiency of the legs

    en.wikipedia.org/wiki/Ultrasonography_of_chronic...

    Doppler measurements using Doppler effect can show the direction of the blood flow and its relative velocity, and color Doppler is the provision of color to help interpret the image, showing, for example, the blood flow toward the probe in one color and that flowing away in another. While the equipment itself is costly, the procedure is not.

  5. Doppler echocardiography - Wikipedia

    en.wikipedia.org/wiki/Doppler_echocardiography

    Doppler echocardiography is a procedure that uses Doppler ultrasonography to examine the heart. [1] An echocardiogram uses high frequency sound waves to create an image of the heart while the use of Doppler technology allows determination of the speed and direction of blood flow by utilizing the Doppler effect.

  6. Arterial resistivity index - Wikipedia

    en.wikipedia.org/wiki/Arterial_resistivity_index

    The arterial resistivity index (also called as Resistance index, abbreviated as RI), developed by Léandre Pourcelot , is a measure of pulsatile blood flow that reflects the resistance to blood flow caused by microvascular bed distal to the site of measurement. It is primarily used in ultrasound imaging to evaluate arteries and solid organ damage.

  7. Peripheral artery disease - Wikipedia

    en.wikipedia.org/wiki/Peripheral_artery_disease

    Buerger's test is an assessment of arterial sufficiency, which is the ability of the artery to supply oxygenated blood to the tissue that it goes to. Nonhealing lower extremity wound [38] If peripheral artery disease is suspected, the initial study is the ankle–brachial index (ABI). [20]

  8. Aortic valve area calculation - Wikipedia

    en.wikipedia.org/wiki/Aortic_valve_area_calculation

    From these, it is easy to calculate the area (in cm 2) of the aortic valve by simply dividing the LV stroke volume (in cm 3) by the AV VTI (in cm) measured on the spectral Doppler display using continuous-wave Doppler. [citation needed] Stroke volume = 0.785(π/4) x Diameter 2 x VTI of LVOT Cross sectional area of LVOT = 0.785(π/4) x LVOT ...

  9. Pulse wave velocity - Wikipedia

    en.wikipedia.org/wiki/Pulse_wave_velocity

    The theory of the velocity of the transmission of the pulse through the circulation dates back to 1808 with the work of Thomas Young. [9] The relationship between pulse wave velocity (PWV) and arterial wall stiffness can be derived from Newton's second law of motion (=) applied to a small fluid element, where the force on the element equals the product of density (the mass per unit volume ...