Search results
Results from the WOW.Com Content Network
This leads to the foreground (blue vector) and background (red vector) having nearly the same intensity, resulting in low image contrast. In a phase-contrast microscope, image contrast is increased in two ways: by generating constructive interference between scattered and background light rays in regions of the field of view that contain the ...
The optical transfer function (OTF) of an optical system such as a camera, microscope, human eye, or projector is a scale-dependent description of their imaging contrast. Its magnitude is the image contrast of the harmonic intensity pattern, + (), as a function of the spatial frequency, , while its complex argument indicates a phase shift ...
The passage of many pairs of rays through pairs of adjacent points in the sample (and their absorbance, refraction and scattering by the sample) means an image of the sample will now be carried by both the 0° and 90° polarised light. These, if looked at individually, would be bright field images of the sample, slightly offset from each other ...
With the sample system built, all that is needed is an epifluorescence microscope and a CCD camera to make quantitative intensity measurements. This is a diagram of an example FLIC experimental setup with silicon, three oxide layers and a fluorescently labeled lipid bilayer (the yellow stars represent fluorophores.
The advantages of these methods compared to normal absorption-contrast X-ray imaging is higher contrast for low-absorbing materials (because phase shift is a different mechanism than absorption) and a contrast-to-noise relationship that increases with spatial frequency (because many phase-contrast techniques detect the first or second ...
Colors outside the sRGB triangle are clipped toward the sRGB white point, so they have more accurate hues. The original image (and most other images of this type) clips each sRGB channel independently to zero, which among other things leads to the whole top of the diagram being colored #00FF00 (sRGB primary green) when it should be more of a cyan.
The effect of the contrast transfer function can be seen in the alternating light and dark rings (Thon rings), which show the relation between contrast and spatial frequency. The contrast transfer function (CTF) mathematically describes how aberrations in a transmission electron microscope (TEM) modify the image of a sample.
Contrary to conventional phase contrast images [citation needed], phase shift images of living cells are suitable to be processed by image analysis software. This has led to the development of non-invasive live cell imaging and automated cell culture analysis systems based on quantitative phase contrast microscopy. [6]