A photoplethysmogram (PPG) is an optically obtained plethysmogram that can be used to detect blood volume changes in the microvascular bed of tissue. [1] [2] A PPG is often obtained by using a pulse oximeter which illuminates the skin and measures changes in light absorption. [3]
Although water is nearly transparent in the range of visible light, it becomes absorbing over the near-infrared region. Water is a critical component since its concentration is high in human tissue. The absorption spectrum of water in the range from 250 to 1000 nm is shown in Figure 2.
Free-electron laser: A broad wavelength range (0.1 nm - several mm); a single FEL may be tunable over a wavelength range Relativistic electron beam: Atmospheric research, material science, medical applications. CO₂ gas dynamic laser: Several lines around 10.5 μm; other frequencies may be possible with different gas mixtures
A sphygmomanometer (/ ˌ s f ɪ ɡ m oʊ m ə ˈ n ɒ m ɪ t ə r / SFIG-moh-mə-NO-mi-tər), also known as a blood pressure monitor, or blood pressure gauge, is a device used to measure blood pressure, composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner, [1] and a mercury or aneroid manometer to measure the pressure.
The type of detector used depends primarily on the range of wavelengths to be measured. Silicon-based CCDs are suitable for the shorter end of the NIR range, but are not sufficiently sensitive over most of the range (over 1000 nm). InGaAs and PbS devices are more suitable and have higher quantum efficiency for wavelengths above 1100 nm. It is ...
Blood pressure pulse waves for quality control – further pulse wave analysis provides additional cardiovascular parameters such as stroke volume, cardiac output and arterial stiffness. Different blood pressure information according to time resolution. A high demand for easily applicable and accurate CNAP-systems is proven.
A more accurate value of systolic blood pressure can be obtained with a sphygmomanometer and palpating the radial pulse. [11] Methods using constitutive models have been proposed to measure blood pressure from radial artery pulse. [citation needed] The diastolic blood pressure cannot be estimated by this method. The American Heart Association ...
For example, with one point per wavelength of a HeNe reference laser at 0.633 μm (15 800 cm −1) the shortest wavelength would be 1.266 μm (7900 cm −1). Because of aliasing , any energy at shorter wavelengths would be interpreted as coming from longer wavelengths and so has to be minimized optically or electronically.