  2. Steinmetz's equation - Wikipedia

    en.wikipedia.org/wiki/Steinmetz's_equation

    The equation is used mainly to calculate core losses in ferromagnetic magnetic cores used in electric motors, generators, transformers and inductors excited by sinusoidal current. Core losses are an economically important source of inefficiency in alternating current (AC) electric power grids and appliances.

  3. Losses in electrical systems - Wikipedia

    en.wikipedia.org/wiki/Losses_in_electrical_systems

    In an electrical or electronic circuit or power system part of the energy in play is dissipated by unwanted effects, including energy lost by unwanted heating of resistive components (electricity is also used for the intention of heating, which is not a loss), the effect of parasitic elements (resistance, capacitance, and inductance), skin effect, losses in the windings and cores of ...

  4. Electrical efficiency - Wikipedia

    en.wikipedia.org/wiki/Electrical_efficiency

    An electronic amplifier that delivers 10 watts of power to its load (e.g., a loudspeaker), while drawing 20 watts of power from a power source is 50% efficient. (10/20 × 100 = 50%) Electric kettle: more than 90% [citation needed] (comparatively little heat energy is lost during the 2 to 3 minutes a kettle takes to boil water).

  5. Load-loss factor - Wikipedia

    en.wikipedia.org/wiki/Load-loss_factor

    Multiple empirical formulae exist that relate the loss factor to the load factor (Dickert et al. in 2009 listed nine [5]). Similarly, the ratio between the average and the peak current is called form coefficient k [ 6 ] or peak responsibility factor k , [ 7 ] its typical value is between 0.2 to 0.8 for distribution networks and 0.8 to 0.95 for ...

  6. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    In electrical engineering the load factor is defined as the average load divided by the peak load in a specified time period. [1] It is a measure of the utilization rate, or efficiency of electrical energy usage; a high load factor indicates that load is using the electric system more efficiently, whereas consumers or generators that underutilize the electric distribution will have a low load ...

  7. Voltage drop - Wikipedia

    en.wikipedia.org/wiki/Voltage_drop

    The voltage drop across the load is proportional to the power available to be converted in that load to some other useful form of energy. For example, an electric space heater may have a resistance of ten ohms, and the wires that supply it may have a resistance of 0.2 ohms, about 2% of the total circuit resistance. This means that approximately ...

  8. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    Efficiency of power plants, world total, 2008. Energy conversion efficiency (η) is the ratio between the useful output of an energy conversion machine and the input, in energy terms. The input, as well as the useful output may be chemical, electric power, mechanical work, light (radiation), or heat. The resulting value, η (eta), ranges ...

  9. Standby power - Wikipedia

    en.wikipedia.org/wiki/Standby_power

    Standby power, also called vampire power [1], vampire draw, phantom load, ghost load, or leaking electricity, refers to how electronic and electrical appliances consume electric power. At the same time, they are switched off (but are designed to draw some power) or in standby mode. It only occurs because some devices claim to be "switched off ...