Search results
Results from the WOW.Com Content Network
In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same ...
Analog multimeter Digital multimeter. A multimeter (also known as a volt-ohm-milliammeter, volt-ohmmeter or VOM) [1] is a measuring instrument that can measure multiple electrical properties. [2] [3] A typical multimeter can measure voltage, resistance, and current, [4] in which case can be used as a voltmeter, ohmmeter, and ammeter.
In the semiconductor industry, Cross-Bridge Kelvin Resistor(CBKR) structures are the mostly used test structures to characterize metal-semiconductor contacts in the Planar devices of VLSI technology. During the measurement process, force the current ( I {\displaystyle I} ) between contacts 1 and 2 and measure the potential deference between ...
Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.
An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. [1] In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value.
An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high-voltage source and voltage and current meters. A single instrument called a "pressure test set" or "hipot tester" is often used to perform this test.
An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.
One was connected via a series resistor to the battery supply. The second was connected to the same battery supply via a second resistor and the resistor under test. The indication on the meter was proportional to the ratio of the currents through the two coils. This ratio was determined by the magnitude of the resistor under test.