A Benchtop nuclear magnetic resonance spectrometer (Benchtop NMR spectrometer) refers to a Fourier transform nuclear magnetic resonance (FT-NMR) spectrometer that is significantly more compact and portable than the conventional equivalents, such that it is portable and can reside on a laboratory benchtop. This convenience comes from using ...
Bench top spectrum analyzers normally have multiple fans (with associated vents) to dissipate heat produced by the processor. Due to their architecture, bench top spectrum analyzers typically weigh more than 30 pounds (14 kg). Some bench top spectrum analyzers offer optional battery packs, allowing them to be used away from AC power. This type ...
A 900 MHz NMR instrument with a 21.1 T magnet at HWB-NMR, Birmingham, UK Nuclear magnetic resonance spectroscopy, most commonly known as NMR spectroscopy or magnetic resonance spectroscopy (MRS), is a spectroscopic technique based on re-orientation of atomic nuclei with non-zero nuclear spins in an external magnetic field.
Utility converts between mass spectrometer file formats, e.g. to convert proprietary binary files to MGF peak list files, to prepare for upload to Proteome Cluster. Multimaging Proprietary Software for mass spectrometry imaging designed to normalize, validate and interpret MS images. multiMS-toolbox Open source
Fourier-transform ion cyclotron resonance (FTICR) mass spectrometry is a high-resolution technique that can be used to determine masses with high accuracy. Many applications of FTICR-MS use this mass accuracy to help determine the composition of molecules based on accurate mass.
The sector instrument geometry consists of a 127.30° () electric sector without an initial drift length followed by a 60° magnetic sector with the same direction of curvature. Sometimes called a "Bainbridge mass spectrometer," this configuration is often used to determine isotopic masses.
A secondary ion mass spectrometer consists of (1) a primary ion gun generating the primary ion beam, (2) a primary ion column, accelerating and focusing the beam onto the sample (and in some devices an opportunity to separate the primary ion species by Wien filter or to pulse the beam), (3) high vacuum sample chamber holding the sample and the ...
The MPR has a 700 mm long cylindrical steel neutron collimator with a 10-cm2 bore. At a distance 170 mm behind the end of the collimator is placed a 10 cm2 polythene conversion foil, defining the active area of the spectrometer. The collimator-foil arrangement defines the spectrometers field-of-view into the plasma.