Ads
related to: butterfly dampers for ductwork wallsupplyhouse.com has been visited by 100K+ users in the past month
- HVAC & Air Quality
Exclusive Bundle Offers
Save Big on Wide Range of Products
- Radiant Heat & Heating
Choose from Wide Range of Products
Reliable Fast Shipping
- Heating Supplies
Including Pumps, Boilers, Radiant
Heat Supplies, and More. Shop Now!
- PEX Products
Shop Our Wide Selection of Reliable
PEX Products at Low Prices.
- HVAC & Air Quality
zoro.com has been visited by 100K+ users in the past month
Search results
Results from the WOW.Com Content Network
This damper can switch the electrical power to control additional "slave" dampers, minimizing the electrical load on the damper's control circuitry and power transformer. A zone damper (also known as a Volume Control Damper or VCD) is a specific type of damper used to control the flow of air in an HVAC heating or cooling system. In order to ...
An unlouvered wall register, which allows circulation of air from one floor to another. Registers vary in size with the heating and cooling requirements of the room. [5] If a register is too small, the HVAC system will need to push air through the ducts at a faster rate in order to achieve the desired heating or cooling.
Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to ...
These systems rely on ductwork, vents, and plenums as means of air distribution, separate from the actual heating and air conditioning systems. The return plenum carries the air from several large return grills (vents) to a central air handler for re-heating. The supply plenum directs air from the central unit to the rooms which the system is ...
Smoke damper may be used to prevent the spread of smoke from the space of fire origin to other spaces in the same building. A combination of fans and dampers can exhaust smoke from an area while pressurizing the smoke-free areas around the affected area (inhibiting smoke infiltration into additional areas).
Most systems will use motorized dampers to control the air mixing, and controlled by the building management system (BMS), or controls system. Typically as the fresh air and exhaust air dampers are driven from 0% open to 100% open, the mixing damper will in turn be driven from 100% open to 0% open, so as to always ensure a constant volume of ...
Ads
related to: butterfly dampers for ductwork wallsupplyhouse.com has been visited by 100K+ users in the past month
zoro.com has been visited by 100K+ users in the past month