enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation. [4] = Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree ...

  3. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).

  4. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  5. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    If lead b is positive, the electrical heart axis can be estimated to lie within the quadrant between axis of lead a and lead b. A simple tool to quickly identify axis deviation (Figure 3) is the popular mnemonic; R eaching for R ight Axis Deviation and L eaving for L eft Axis Deviation.

  6. Cardiac resynchronization therapy - Wikipedia

    en.wikipedia.org/wiki/Cardiac_resynchronization...

    The leads are: - Atrial lead at the right appendage - Right ventricular lead at the apex - Left ventricular lead through the coronary sinus. [7] CRT requires the placement of an electrical device for biventricular pacing, along with placement of (at least) two pacing leads, to facilitate stable left ventricular and right ventricular pacing.

  7. 10–20 system (EEG) - Wikipedia

    en.wikipedia.org/wiki/10–20_system_(EEG)

    The Fp2, F8, T4, T6, and O2 electrodes are placed at intervals of 5%, 10%, 10%, 10%, 10%, and 5%, respectively, measured above the right ear, from front (Fpz) to back (Oz). The same is done for the odd-numbered electrodes on the left side, to complete the full circumference. Measurement methods for placement of the F3, F4, P3, and P4 points differ.

  8. Heart - Wikipedia

    en.wikipedia.org/wiki/Heart

    This tracing of the electrical signal is the electrocardiogram (ECG) or (EKG). An ECG is a bedside test and involves the placement of ten leads on the body. This produces a "12 lead" ECG (three extra leads are calculated mathematically, and one lead is electrically ground, or earthed). [85]

  9. Right heart strain - Wikipedia

    en.wikipedia.org/wiki/Right_heart_strain

    An important potential finding with echo is McConnell's sign, where only the RV apex wall contracts; [7] it is specific for right heart strain and typically indicates a large PE. [8] On an electrocardiogram (ECG), there are multiple ways RV strain can be demonstrated. A finding of S1Q3T3 [b] is an insensitive [10] sign of right heart strain. [11]