Dry chemical powder is used on all classes of fires. Dry chemical powder puts out the fire by coating the burning material with a thin layer of dust, thereby separating the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire, so these extinguishers are extremely effective at putting out the fire.
Characteristics, performance requirements and test methods. EN 3-8: Portable fire extinguishers. Additional requirements to EN 3-7 for the construction, resistance to pressure and mechanical tests for extinguishers with a maximum allowable pressure equal to or lower than 30 bar.
Purple-K, also known as PKP, is a dry-chemical fire suppression agent used in some dry chemical fire extinguishers. [1] It is the second most effective dry chemical in fighting class B (flammable liquid) fires after Monnex (potassium allophanate), and can be used against some energized electrical equipment fires (USA class C fires). [2]
Fire extinguishing capacity is rated in accordance with ANSI/UL 711: Rating and Fire Testing of Fire Extinguishers. The ratings are described using numbers preceding the class letter, such as 1-A:10-B:C.
Fire test in Sweden, showing rapid fire spread through burning of cable jackets from one cable tray to another. A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation.
Fire control is the practice of reducing the heat output of a fire, reducing the area over which the fire exists, or suppressing or extinguishing the fire by depriving it of fuel, oxygen, or heat (see fire triangle). Fire prevention and control is the prevention, detection, and extinguishment of fires, including such secondary activities as ...
The larger the burn pan fire, the larger the rating and the longer the extinguisher must discharge to be able to handle the larger volume of fire before running out. For a given size extinguisher the resulting effect is a lower flow rate, resulting in a higher UL rating. Generally for same size extinguishers (agent capacity)
Gaseous fire suppression, also called clean agent fire suppression, is the use of inert gases and chemical agents to extinguish a fire. These agents are governed by the National Fire Protection Association (NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere.