enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Blank (solution) - Wikipedia

    en.wikipedia.org/wiki/Blank_(solution)

    A blank solution is a solution containing little to no analyte of interest, [1] usually used to calibrate instruments such as a colorimeter. According to the EPA, the "primary purpose of blanks is to trace sources of artificially introduced contamination." [2] Different types of blanks are used to identify the source of contamination in the ...

  3. Bradford protein assay - Wikipedia

    en.wikipedia.org/wiki/Bradford_protein_assay

    Turn on and adjust a spectrophotometer to a wavelength of 595 nm, and blank the spectrophotometer using 1.5 mL cuvettes or use a mobile smartphone camera (RGBradford method). [9] Wait 2 minutes and read the absorbance of each standard and sample at 595 nm. Plot the absorbance of the standards vs. their concentration.

  4. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    Spectrophotometry is a branch of electromagnetic spectroscopy concerned with the quantitative measurement of the reflection or transmission properties of a material as a function of wavelength. [2] Spectrophotometry uses photometers , known as spectrophotometers, that can measure the intensity of a light beam at different wavelengths.

  5. Dark current (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Dark_current_(chemistry)

    In analytical chemistry, dark current refers to the constant response produced by a photodetector, even in the absence of radiation. [1] The nonzero response can be due to the random thermal excitation of electrons in the detector, which is brought up to measurable levels by amplification.

  6. Cuvette - Wikipedia

    en.wikipedia.org/wiki/Cuvette

    Analyses are performed by using a conventional scanning spectrophotometer and the usual laboratory cuvette (special vial) that fits into the sample cavity of the instrument. [7] Fingerprints and droplets of water disrupt light rays during measurement, so low-lint gauze or cloth may be used to wipe clean the outer surface of a cuvette before use ...

  7. Blank value - Wikipedia

    en.wikipedia.org/wiki/Blank_value

    A blank value in analytical chemistry is a measurement of a blank. The reading does not originate from a sample, but the matrix effects , reagents and other residues . These contribute to the sample value in the analytical measurement and therefore have to be subtracted.

  8. Absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Absorption_spectroscopy

    An overview of electromagnetic radiation absorption. This example discusses the general principle using visible light.A white beam source – emitting light of multiple wavelengths – is focused on a sample (the complementary color pairs are indicated by the yellow dotted lines).

  9. VIT signals - Wikipedia

    en.wikipedia.org/wiki/VIT_signals

    In each field vertical blanking is about 1612 μs in System B (also G and H; analogue system in most of Europe) and 1333 μs in System M (analogue TV system in USA). This duration is equal to 25 lines in system B and 21 lines in system M. [2] Although 7.5 lines are used for synchronization of the image, the remaining lines can be used for other purposes. [3]