  1. Results from the WOW.Com Content Network
  2. Zinsco - Wikipedia

    en.wikipedia.org/wiki/Zinsco

    Zinsco would remain with copper in both their panels and breakers until the third major copper shortage in the early 1960s, when they would switch to an aluminum bus. In 1963, Zinsco introduced the R-38 twin breaker, which was the only twin circuit breaker that also made contact on both bus-bars for 240 volts in a single breaker space.

  3. Stab-Lok - Wikipedia

    en.wikipedia.org/wiki/Stab-Lok

    Angie's List and NBC Bay Area both highlighted an October 2002 ruling in a New Jersey Superior Court, which found that FPE (Federal Pacific Electric), the manufacturer of the Stab-Lok breakers and panels, "knowingly and purposefully [sic] distributed circuit breakers which were not tested to meet UL standards as indicated on their label". [8]

  4. Ring main unit - Wikipedia

    en.wikipedia.org/wiki/Ring_main_unit

    In an electrical power distribution system, a ring main unit (RMU) is a factory assembled, metal enclosed set of switchgear used at the load connection points of a ring-type distribution network. It includes in one unit two switches that can connect the load to either or both main conductors, and a fusible switch or circuit breaker and switch ...

  5. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a solenoid to trip the mechanism, and an electric motor to restore energy to springs (which rapidly separate contacts when the breaker is tripped).

  7. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    Contact load in amperes for heaters (AC1) and motors (AC3) can be found directly on the contactor. The "Utilization category" are mainly categorized in IEC 60947 in the following volume: Volume 1: General requirements; Volume 2: Circuit-breakers; Volume 3: Circuit-breakers, circuit-breakers, switch-disconnectors and switch-fuse units