Modes of mechanical ventilation are one of the most important aspects of the usage of mechanical ventilation.The mode refers to the method of inspiratory support. In general, mode selection is based on clinician familiarity and institutional preferences, since there is a paucity of evidence indicating that the mode affects clinical outcome.
Mandatory minute ventilation (MMV) (also called minimum minute ventilation) is a mode of mechanical ventilation which requires the operator to determine what the appropriate minute ventilation for the patient should be and the ventilator then monitors the patient's ability to generate this volume. If the calculation suggests the volume target ...
Total lung capacity: the volume in the lungs at maximal inflation, the sum of VC and RV. TV: Tidal volume: that volume of air moved into or out of the lungs in 1 breath (TV indicates a subdivision of the lung; when tidal volume is precisely measured, as in gas exchange calculation, the symbol TV or V T is used.) RV
Endobronchial valves are medical devices that allow air to exit these sections but not to re-enter. The valves, in effect, cause damaged lung tissue to deflate, thereby reducing the excessive lung volume (hyperinflation) caused by emphysema. Two endobronchial valves have been approved by the FDA for BLVR: Zephyr and Spiration. [citation needed]
Minute ventilation (or respiratory minute volume or minute volume) is the volume of gas inhaled (inhaled minute volume) or exhaled (exhaled minute volume) from a person's lungs per minute. It is an important parameter in respiratory medicine due to its relationship with blood carbon dioxide levels .
Ventilators may also be equipped with monitoring and alarm systems for patient-related parameters (e.g., pressure, volume, and flow) and ventilator function (e.g., air leakage, power failure, mechanical failure), backup batteries, oxygen tanks, and remote control. The pneumatic system is nowadays often replaced by a computer-controlled turbopump.
Mechanical dead space is another important parameter in ventilator design and function, and is defined as the volume of gas breathed again as the result of use in a mechanical device. Image of endotracheal tube placement required to connect a patient's physiologic airway to the ventilator.
A resuscitator is a device using positive pressure to inflate the lungs of an unconscious person who is not breathing, in order to keep them oxygenated and alive. [citation needed] There are three basic types: a manual version (also known as a bag valve mask) consisting of a mask and a large hand-squeezed plastic bulb using ambient air, or with supplemental oxygen from a high-pressure tank.