  2. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  3. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  4. Window insulation - Wikipedia

    en.wikipedia.org/wiki/Window_insulation

    The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. [1] The U-factor of a window can often be found on the rating label of the window. Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units.

  5. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  6. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    The U-factor or U-value is the overall heat transfer coefficient and can be found by taking the inverse of the R-value. It is a property that describes how well building elements conduct heat per unit area across a temperature gradient.

  7. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  8. What is a factor rate and how to calculate it - AOL

    www.aol.com/finance/factor-rate-calculate...

    How to calculate a factor rate. Using the factor rate provided by the lender, you can quickly calculate the cost of the borrowed funds. For example, if you borrowed $100,000 with a factor rate of ...

  9. Tog (unit) - Wikipedia

    en.wikipedia.org/wiki/Tog_(unit)

    The basic unit of insulation coefficient is the R SI, (1 m 2 ⋅K/W). 1 tog = 0.1 R SI.There is also a US clothing unit, the clo, equivalent to 0.155 R SI or 1.55 tog, described in ASTM D-1518.