A sound attenuator, or duct silencer, sound trap, or muffler, is a noise control acoustical treatment of Heating Ventilating and Air-Conditioning (HVAC) ductwork designed to reduce transmission of noise through the ductwork, either from equipment into occupied spaces in a building, or between occupied spaces.
The STC results of decoupling in wall and ceiling assemblies varies significantly depending on the framing type, air cavity volume, and decoupling material type. [14] Great care must be taken in each type of decoupled partition construction, as any fastener that becomes mechanically (rigidly) coupled to the framing can undermine the decoupling ...
The Sound Reduction Index is expressed in decibels (dB). It is the weighted sound reduction index for a partition or single component only. This is a laboratory-only measurement, which uses knowledge of the relative sizes of the rooms in the test suite, and the reverberation time in the receiving room, and the known level of noise which can pass between the rooms in the suite by other routes ...
Architectural acoustics can be about achieving good speech intelligibility in a theatre, restaurant or railway station, enhancing the quality of music in a concert hall or recording studio, or suppressing noise to make offices and homes more productive and pleasant places to work and live in. [3] Architectural acoustic design is usually done by ...
Data acquisition hardware for acoustic measurements typically utilizes 24-bit analog-to-digital converters (ADCs), anti-aliasing filters, and other signal conditioning. This signal conditioning may include amplification, filtering, sensor excitation, and input configuration. Another consideration is the frequency range of the instrumentation.
Noise curves are a common way to characterise background noise in unoccupied buildings and spaces. [1] Their purpose is to produce a single-value representation of a complete sound spectrum. International standards organizations ( ISO , [ 2 ] ANSI [ 3 ] and ASA ) recognize the need to objectify judgements on the amount of ambient noise in ...
The commonly used reference sound exposure in air is [2] E 0 = 400 μ P a 2 ⋅ s . {\displaystyle E_{0}=400~\mathrm {\mu Pa^{2}\cdot s} .} The proper notations for sound exposure level using this reference are L W /(400 μPa 2 ⋅s) or L W (re 400 μPa 2 ⋅s) , but the notations dB SEL , dB(SEL) , dBSEL, or dB SEL are very common, even if ...
A reverberation chamber is used to test the sound absorption coefficients and NRC of a material. The noise reduction coefficient (commonly abbreviated NRC) is a single number value ranging from 0.0 to 1.0 that describes the average sound absorption performance of a material. An NRC of 0.0 indicates the object does not attenuate mid-frequency ...