Safety relays must always be designed in such a way that, if wired correctly, neither a fault in the device nor an external fault caused by the sensor or actuator will lead to the loss of the safety function. [8] A normal relay uses a wire coil and the mechanical movement of the metal contacts to switch the load on and off.
In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. [ 1 ] : 4 The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, overvoltage , reverse power flow ...
A relay Electromechanical relay principle Electromechanical relay schematic showing a control coil, four pairs of normally open and one pair of normally closed contacts An automotive-style miniature relay with the dust cover taken off. A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple ...
The non-tripped state is typically 24 VDC, and the tripped state (when the safety barrier has been violated) 0 VDC. If a wire were to break between the light curtain and the safety relay, the safety relay would trip to the safe state. The OSSD outputs are self-checked. In the non-tripped state, the outputs periodically pulse low.
In older plug designs both blades were the same width, so the plug could be inserted into the receptacle either way around. Many plugs manufactured since 1948 are polarized; the neutral blade is 5 ⁄ 16 in or 7.9 mm wide, 1 ⁄ 16 in or 1.6 mm wider than the line blade, so the plug can be inserted only one way. Polarized 1-15P plugs will not ...
A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...
IEC 60309 (formerly IEC 309 and CEE 17, also published by CENELEC as EN 60309) is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes".
An earth-leakage protection device is a safety device used in electrical installations to prevent shock. It consists of either a current sensing mechanism, or a voltage sensing mechanism. Such devices may be found in the form of either a circuit breaker , known as an earth-leakage circuit breaker ( ELCB ), or built into a socket (aka receptacle ) .