A fire escape is a type of external emergency exit. Local building codes or building regulations often dictate the number of fire exits required for a building of a given size, including the number of stairwells. For any buildings bigger than a private house, modern codes invariably specify at least two sets of stairs, completely isolated from ...
An alternative form of rapid-exit fire escape developed in the early 1900s was a long canvas tube suspended below a large funnel outside the window of a tall building. A person escaping the fire would slide down the interior of the tube, and could control the speed of descent by pushing outward on the tube walls with their arms and legs.
A fire drill is a method of practicing how a building should evacuate in the event of a fire or other emergencies. In most cases, the building's existing fire alarm system is activated and the building is evacuated by means of the nearest available exits, as if an emergency had actually occurred. Fire drill procedures may vary depending on the ...
ISO 7010 standard (1987) exit sign, used since 1982 in Japan. The strategy of individuals in evacuating buildings has been investigate in many disaster in the last 50 years. The complexity of the building, the pre-movement decisions and the movement ability of the individuals represent to majior factors influencing building evacuations.
In building safety and construction, a smokeproof enclosure is a type of exit stairwell that has been designed to keep out smoke (and other combustion products) in the event of a fire, so that building occupants may more safely exit the building.
Fire detection – fire alarm systems and brigade call systems; Active fire protection – fire suppression systems; Passive fire protection – fire and smoke barriers, space separation; Smoke control and management; Escape facilities – emergency exits, fire lifts, etc. Building design, layout, and space planning; Fire prevention programs
A demonstration of a fire escape chute on the streets of Daegu, South Korea. An escape chute is a special kind of emergency exit, used where conventional fire escape stairways are impractical. The chute is a fabric (or occasionally metal) tube installed near a special exit on an upper floor or roof of a building, or a tall structure.
An area of refuge or safe room [1] is a place in a building designed to hold occupants during a fire or other emergency when evacuation may not be safe or possible. Occupants can wait there until rescued or relieved by firefighters.