The first soil resistance measuring instrument was invented in the 1950s by Evershed & Vignoles Meggers who made the first insulation and earth resistance testers. [2] One of the most used analog grounding testers in USSR were М416. [3] From the 21st century several companies produced digital earth resistance meters and testers.
The method of measuring subsurface resistivity involves placing four electrodes in the ground in a line at equal spacing, applying a measured AC current to the outer two electrodes, and measuring the AC voltage between the inner two electrodes. A measured resistance is calculated by dividing the measured voltage by the measured current.
Electrical resistance survey of an archaeological site using a twin probe system. In most systems, metal probes (electrodes) are inserted into the ground to obtain a reading of the local electrical resistance. A variety of probe configurations are used, most having four probes, often mounted on a rigid frame. In these systems, two of the probes ...
Download as PDF; Printable version ... High resistance grounding system grounds the neutral through a resistance which limits the ground fault current to a value ...
Electrical resistance meters can be thought of as similar to the Ohmmeters used to test electrical circuits. In most systems, metal probes are inserted into the ground to obtain a reading of the local electrical resistance. A variety of probe configurations are used, most having four probes, often mounted on a rigid frame.
BS5930:2015 is a further full revision of the standard, and introduces some principal changes including: compliance with BS EN 1997-1 and BS EN 1997-2 and related test standards; new information on geophysical surveying and ground testing, and updated guidance on desk studies, field reconnaissance, ground investigations on contaminated ground ...
A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.
Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration. ASTM Standard C1202-10. Standard Test Method for Surface Resistivity of Concrete's Ability to Resist Chloride Ion Penetration. Washington, D.C., USA: American Association of State Highway and Transportation Officials. 2011. AASHTO TP 95.