enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Nucleic acid quantitation - Wikipedia

    en.wikipedia.org/wiki/Nucleic_acid_quantitation

    In essence, the Beer Lambert Law makes it possible to relate the amount of light absorbed to the concentration of the absorbing molecule. The following absorbance units to nucleic acid concentration conversion factors are used to convert OD to concentration of unknown nucleic acid samples: [5] A260 dsDNA = 50 μg/mL A260 ssDNA = 33 μg/mL

  3. Molar absorption coefficient - Wikipedia

    en.wikipedia.org/wiki/Molar_absorption_coefficient

    c is the molar concentration of those species; ℓ is the path length. Different disciplines have different conventions as to whether absorbance is decadic (10-based) or Napierian (e-based), i.e., defined with respect to the transmission via common logarithm (log 10) or a natural logarithm (ln). The molar absorption coefficient is usually decadic.

  4. Reaction progress kinetic analysis - Wikipedia

    en.wikipedia.org/wiki/Reaction_progress_kinetic...

    where [A] 0 is the amount, absorbance, or concentration of substrate initially present and [A] t is the amount, absorbance, or concentration of that reagent at time, t. Normalizing data to fractional conversion may be particularly helpful as it allows multiple reactions run with different absolute amounts or concentrations to be compared on the ...

  5. Absorbance - Wikipedia

    en.wikipedia.org/wiki/Absorbance

    Absorbance is defined as "the logarithm of the ratio of incident to transmitted radiant power through a sample (excluding the effects on cell walls)". [1] Alternatively, for samples which scatter light, absorbance may be defined as "the negative logarithm of one minus absorptance, as measured on a uniform sample". [2]

  6. Variable pathlength cell - Wikipedia

    en.wikipedia.org/wiki/Variable_pathlength_cell

    Variable pathlength absorption spectroscopy uses a determined slope to calculate concentration. As stated above this is a product of the molar absorptivity and the concentration. Since the actual absorbance value is taken at many data points at equal intervals, background subtraction is generally unnecessary.

  7. Atomic absorption spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Atomic_absorption_spectroscopy

    The difference in intensity is directly proportional to the concentration of the analyte in the sample, following the Beer-Lambert law: * **A = εcl**, where: * A is the absorbance measured. * ε is the molar absorptivity (constant specific to the element and wavelength). * c is the concentration of the analyte.

  8. Isosbestic point - Wikipedia

    en.wikipedia.org/wiki/Isosbestic_point

    The spectra of basic, acid and intermediate pH solutions are shown. The analytical concentration of the dye is the same in all solutions. In spectroscopy, an isosbestic point is a specific wavelength, wavenumber or frequency at which the total absorbance of a sample does not change during a chemical reaction or a physical change of the sample ...

  9. Absorption (chemistry) - Wikipedia

    en.wikipedia.org/wiki/Absorption_(chemistry)

    Chemical absorption or reactive absorption is a chemical reaction between the absorbed and the absorbing substances. Sometimes it combines with physical absorption. This type of absorption depends upon the stoichiometry of the reaction and the concentration of its reactants. They may be carried out in different units, with a wide spectrum of ...