enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.

  3. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Breakers for protections against earth faults too small to trip an over-current device: Residual-current device (RCD), or residual-current circuit breaker (RCCB) — detects current imbalance, but does not provide over-current protection. In the United States and Canada, these are called ground fault circuit interrupters (GFCI).

  4. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    Normally, a main switch, and in recent boards, one or more residual-current devices (RCDs) or residual current breakers with overcurrent protection (RCBOs) are also incorporated. In the United Kingdom, a distribution board designed for domestic installations is known as a consumer unit .

  5. Talk:Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Talk:Residual-current_device

    A residual-current device (RCD), or residual-current circuit breaker (RCCB), is a device that instantly breaks an electric circuit to prevent serious harm from an ongoing electric shock. A fuse or circuit breaker also does that, 'instantly' of course, is subject to qualification.

  6. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    To eliminate this confusion, the IEC decided to apply the term residual current device (RCD) to differential-current-operated ELCBs. Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current.

  7. Appliance classes - Wikipedia

    en.wikipedia.org/wiki/Appliance_classes

    To provide supplementary protection against high-impedance faults it is common to recommend a residual-current device (RCD) also known as a residual current circuit breaker (RCCB), ground fault circuit interrupter (GFCI), or residual current operated circuit-breaker with integral over-current protection (RCBO), which will cut off the supply of ...

  8. 15 Black Friday deals that are worth the splurge: Le Creuset ...

    www.aol.com/lifestyle/11-black-friday-deals-that...

    The Solawave is a 4-in-1 wand that provides red light therapy, therapeutic warmth to soothe skin and reduce dark circles, a facial massage to reduce puffiness and a stimulating galvanic current to ...

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...