Search results
Results from the WOW.Com Content Network
The power factor in a single-phase circuit (or balanced three-phase circuit) can be measured with the wattmeter-ammeter-voltmeter method, where the power in watts is divided by the product of measured voltage and current. The power factor of a balanced polyphase circuit is the same as that of any phase. The power factor of an unbalanced ...
Because the voltage of a single phase system reaches a peak value twice in each cycle, the instantaneous power is not constant. Standard frequencies of single-phase power systems are either 50 or 60 Hz. Special single-phase traction power networks may operate at 16.67 Hz or other frequencies to power electric railways. [1]
As an example of how per-unit is used, consider a three-phase power transmission system that deals with powers of the order of 500 MW and uses a nominal voltage of 138 kV for transmission. We arbitrarily select S b a s e = 500 M V A {\displaystyle S_{\mathrm {base} }=500\,\mathrm {MVA} } , and use the nominal voltage 138 kV as the base voltage ...
Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line for supplying single-phase electrical power to remote areas at low cost. It is principally used for rural electrification, but also finds use for larger isolated loads such as water pumps. Single-wire earth return is also used for HVDC over submarine ...
The steam engines were also used during the twentieth century in power stations for traction networks which had single-phase power distribution for specific railways. A special set of single-phase generators with steam turbines at Waterside Generating Station in New York City in 1938 was an example of such generation and distribution systems ...
From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an ...
The vector sum of V R and the voltage drops equals V S, and it is apparent in the diagrams that V S does not equal V R in magnitude or phase angle. Voltage phasor diagrams for a short transmission line serving lagging, in-phase, and leading loads. The diagrams show that the phase angle of current in the line affects voltage regulation ...
Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...