A basic contactor will have a coil input (which may be driven by either an AC or DC supply depending on the contactor design). Universal coils (driven by AC as well as DC) are also available in the market today. [3] The coil may be energized at the same voltage as a motor the contactor is controlling, or may be separately controlled with a ...
Normally closed mercury relay, with coil around top of tube and adjustable angle. A mercury relay (mercury displacement relay, mercury contactor) is a relay that uses mercury as the switching element. They are used as high-current switches or contactors, where contact erosion from constant cycling would be a problem for conventional relay contacts.
A fan coil unit (FCU), also known as a Vertical Fan Coil Unit (VFCU), is a device consisting of a heat exchanger (coil) and a fan. FCUs are commonly used in HVAC systems of residential, commercial, and industrial buildings that use ducted split air conditioning or central plant cooling.
A magnetic starter has a contactor and an overload relay, which will open the control voltage to the starter coil if it detects an overload on a motor. [1] [2] The overload relay opens a set of contacts that are wired in series with the supply to the contactor feeding the motor. The characteristics of the heaters can be matched to the motor so ...
The heat can be transferred to the surrounding air using radiators, hot water coils (hydro-air), or other heat exchangers. The radiators may be mounted on walls or installed within the floor to produce floor heat. The use of water as the heat transfer medium is known as hydronics. The heated water can also supply an auxiliary heat exchanger to ...
Control of small electromagnetic loads with holding current ≤ 0.2 A; e.g. contactor relays 60947-5-2 A: Protection of circuits, with no rated short-time withstand current: 60947-3 B: Protection of circuits, with a rated short-time withstand current: 60947-3 DC-1: Non Inductive or slightly inductive loads, resistance furnaces, heaters: 60947-4 ...
A pulse to one coil turns the relay on, and a pulse to the opposite coil turns the relay off. This type is widely used where control is from simple switches or single-ended outputs of a control system, and such relays are found in avionics and numerous industrial applications.
The phase coils are traditional wound in a single coil assembly with the 0 to 50% winding section buried below the 50% to 100% windings in a single thermal mass as shown in figures 2 and 3 Figure 4. 3 Coil Assembly. Figure 4 shows an improved 1000 kW 11,000 Volt motor starter autotransformer with Axial cooling fans, Cast resin encapsulated coils,