enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Gas lift - Wikipedia

    en.wikipedia.org/wiki/Gas_lift

    The gas-lift mandrel is a device installed in the tubing string of a gas-lift well onto which or into which a gas-lift valve is fitted. There are two common types of mandrels. In a conventional gas-lift mandrel, a gas-lift valve is installed as the tubing is placed in the well. Thus, to replace or repair the valve, the tubing string must be pulled.

  3. Lifting gas - Wikipedia

    en.wikipedia.org/wiki/Lifting_gas

    This calculation is at sea level at 0 °C. For higher altitudes, or higher temperatures, the amount of lift will decrease proportionally to the air density, but the ratio of the lifting capability of hydrogen to that of helium will remain the same. This calculation does not include the mass of the envelope need to hold the lifting gas.

  4. Airlift pump - Wikipedia

    en.wikipedia.org/wiki/Airlift_pump

    (The compressor is on the surface and no mechanical parts are needed in the well). However airlift wells must be much deeper than the water table to allow for submergence. Air is generally pumped at least as deep under the water as the water is to be lifted. (If the water table is 50 ft below, the air should be pumped 100 feet deep).

  5. Artificial lift - Wikipedia

    en.wikipedia.org/wiki/Artificial_lift

    Artificial lift is the use of artificial means to increase the flow of liquids, such as crude oil or water, from a production well. Generally this is achieved by the use of a mechanical device inside the well (known as pump or velocity string) or by decreasing the weight of the hydrostatic column by injecting gas into the liquid some distance down the well.

  6. Precast concrete lifting anchor system - Wikipedia

    en.wikipedia.org/wiki/Precast_concrete_lifting...

    The configuration (size, position and quantity) of this reinforcement should be supplemented to the element reinforcement design to ensure for adequate capacity of the lifting design. Lifting design is influenced by the steel / concrete interaction of the specific anchor selected. Different load cases are considered by the lifting design ...

  7. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  8. Cascade filling system - Wikipedia

    en.wikipedia.org/wiki/Cascade_filling_system

    A cascade filling system is a high-pressure gas cylinder storage system that is used for the refilling of smaller compressed gas cylinders. [1] [2] In some applications, each of the large cylinders is filled by a compressor, otherwise they may be filled remotely and replaced when the pressure is too low for effective transfer. The cascade ...

  9. Lift coefficient - Wikipedia

    en.wikipedia.org/wiki/Lift_coefficient

    The section lift coefficient is based on two-dimensional flow over a wing of infinite span and non-varying cross-section so the lift is independent of spanwise effects and is defined in terms of ′, the lift force per unit span of the wing. The definition becomes