Search results
Results from the WOW.Com Content Network
requirements for determination of the short circuit current rating of the electrical equipment; protective bonding requirements, terminology, and protection against electric shock; Incoming supply requirements and switching; requirements pertaining to safe torque off, emergency stop, and control circuit protection;
An emergency switch in Japan. On railways, [1] an emergency stop is a full application of the brakes in order to bring a train to a stop as quickly as possible. [2] This occurs either by a manual emergency stop activation, such as a button being pushed on the train to start the emergency stop, or on some trains automatically, when the train has passed a red signal or the driver has failed to ...
Emergency stop pushbuttons; Safety gates; Light beam devices; Pressure sensitive mats; Two-hand controls; Time delay; As such, safety relays monitor a specific function. When connected to other safety relays, they guarantee full monitoring of a plant or machine. [1] They meet the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1. [5]
To make a PLC fail-safe the system does not require energization to stop the drives associated. For example, usually, an emergency stop is a normally closed contact. In the event of a power failure this would remove the power directly from the coil and also the PLC input. Hence, a fail-safe system.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
A shutdown valve (also referred to as SDV or emergency shutdown valve, ESV, ESD, or ESDV; or safety shutoff valve) is an actuated valve designed to stop the flow of a hazardous fluid upon the detection of a dangerous event. This provides protection against possible harm to people, equipment or the environment.
Note: In this example, "Run" represents the status of a bit in the PLC, while "Motor" represents the actual output to the real-world relay that closes the motor's real-world circuit. For safety reasons, an emergency stop ("ES") may be hardwired in series with the "Start" switch, and the relay logic should reflect this.
The safety shutdown system shall shut down the facilities to a safe state in case of an emergency situation, thus protecting personnel, the environment and the asset. The safety shutdown system shall manage all inputs and outputs relative to emergency shutdown (ESD) functions (environment and personnel protection).