  1. Results from the WOW.Com Content Network
  2. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    Visual inspection. A survey without touching anything, and looking at the electrical installation or product before starting any electrical testing. A visual inspection seeks to identify damaged insulation, disconnected wires, incorrect installation, and any other visual issues. Dead testing. Continuity test: a test to check the wiring is correct

  3. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    A dielectric withstand test may be done as a factory test on new equipment, or may be done on apparatus already in service as a routine maintenance test. [2] An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high ...

  4. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    In electrical engineering, an electrical isolation test is a direct current (DC) or alternating current (AC) resistance test that is performed on sub-systems of an electronic system to verify that a specified level of isolation resistance is met. Isolation testing may also be conducted between one or more electrical circuits of the same ...

  5. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    The systems employ insulation materials that have a low permittivity and loss. The permittivity and the loss are dielectric properties of the insulation material. As the systems age, these dielectric properties can change. The dielectric loss can be assessed since it can increase several orders of magnitude during the service life of the systems.

  6. Transformer oil testing - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil_testing

    The transformer oil is filled in the vessel of the testing device. Two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the dielectric oil. A test voltage is applied to the electrodes and is continuously increased up to the breakdown voltage with a constant, standard-compliant slew rate of e.g. 2 kV/s.

  7. Megohmmeter - Wikipedia

    en.wikipedia.org/wiki/Megohmmeter

    Megohmmeter M1101M. A Megohmmeter or insulation resistance tester, is a special type of ohmmeter used to measure the electrical resistance of insulators. [1] Insulating components, for example cable jackets, must be tested for their insulation strength at the time of commissioning and as part of maintenance of high voltage electrical equipment and installations.

  8. Portable appliance testing - Wikipedia

    en.wikipedia.org/wiki/Portable_appliance_testing

    A leakage current test is an alternative to the insulation resistance test. A deficiency of the insulation resistance test is that the DC voltage will not activate electromagnetic switches or internal relays etc. that are common in many modern power tools, computers, and TVs, etc. and therefore it can only test the appliance up to those components.

  9. Insulation system - Wikipedia

    en.wikipedia.org/wiki/Insulation_system

    Basic insulation is any material added to protect a user from accidental contact with energized parts. Supplemental insulation is rated to withstand 1500 volts AC. Double insulation is a design concept where failure of one insulation system will not expose the user to a shock hazard due to the presence of a second independent layer of insulation.