Search results

  1. Results from the WOW.Com Content Network
  2. Compressor characteristic - Wikipedia

    en.wikipedia.org/wiki/Compressor_characteristic

    Due to flow reversal, pressure in the pipe falls and the compressor regains its normal stable operation (let at point B) delivering the gas at higher flow rate (˙). But the control valve still corresponds to the flow rate ˙. Due to this compressor's operating conditions will again return to D through points C and S.

  3. Darcy–Weisbach equation - Wikipedia

    en.wikipedia.org/wiki/Darcy–Weisbach_equation

    The flow rate can be converted to a mean flow velocity V by dividing by the wetted area of the flow (which equals the cross-sectional area of the pipe if the pipe is full of fluid). Pressure has dimensions of energy per unit volume, therefore the pressure drop between two points must be proportional to the dynamic pressure q.

  4. Airlift pump - Wikipedia

    en.wikipedia.org/wiki/Airlift_pump

    This air is usually compressed by a compressor or a blower. The air is injected in the lower part of a pipe that transports a liquid. By buoyancy the air, which has a lower density than the liquid, rises quickly. By fluid pressure, the liquid is taken in the ascendant air flow and moves in the same direction as the air. The calculation of the ...

  5. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  6. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  7. Maximum allowable operating pressure - Wikipedia

    en.wikipedia.org/wiki/Maximum_allowable...

    Maximum Allowable Operating Pressure (MAOP) is a pressure limit set, usually by a government body, which applies to compressed gas pressure vessels, pipelines, and storage tanks. For pipelines, this value is derived from Barlow's Formula , which takes into account wall thickness, diameter, allowable stress (which is a function of the material ...

  8. Darcy friction factor formulae - Wikipedia

    en.wikipedia.org/wiki/Darcy_friction_factor_formulae

    Its value depends on the flow's Reynolds number Re and on the pipe's relative roughness ε / D. The log function is understood to be base-10 (as is customary in engineering fields): if x = log(y), then y = 10 x. The ln function is understood to be base-e: if x = ln(y), then y = e x.

  9. Compressor map - Wikipedia

    en.wikipedia.org/wiki/Compressor_map

    These effects are caused by the sluggish response of the spool (i.e. inertia effects) to rapid changes in engine fuel flow. Compressor surge is a particular problem during slam-accelerations and can be overcome by suitable adjustments to the fueling schedule and/or use of blow-off (bleeding air off the compressor, for handling purposes).