Commercial and distribution transformers rated up to say 2,500 kVA are usually designed with short-circuit impedances of between about 3% and 6% and with a corresponding / ratio (winding reactance/winding resistance ratio) of between about 3 and 6, which defines the percent secondary voltage variation between no-load and full load.
To match the impedances, both cables must be connected to a matching transformer with a turns ratio of 2:1. In this example, the 300-ohm line is connected to the transformer side with more turns; the 75-ohm cable is connected to the transformer side with fewer turns. The formula for calculating the transformer turns ratio for this example is:
A double-tuned transformer from a radio receiver intermediate-frequency amplifier with its screening can removed. A double-tuned amplifier is a tuned amplifier with transformer coupling between the amplifier stages in which the inductances of both the primary and secondary windings are tuned separately with a capacitor across each.
However using port 2 or port 4 as the input results in a 180° hybrid. [30] This fact leads to another useful application of the hybrid ring: it can be used to produce sum (Σ) and difference (Δ) signals from two input signals as shown in figure 12. With inputs to ports 2 and 3, the Σ signal appears at port 1 and the Δ signal appears at port ...
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
Isolation transformer. In classical transformers, there are two electrically separate windings of wire coils around the transformer's core. The advantage of transformer-type over other types of balun is that the electrically separate windings for input and output allow these baluns to connect circuits whose ground-level voltages are subject to ground loops or are otherwise electrically ...
The delta winding allows third-harmonic currents to circulate within the transformer, and prevents third-harmonic currents from flowing in the supply line. [2] Delta-wye transformers introduce a 30, 150, 210, or 330 degree phase shift. [3] Thus they cannot be paralleled with wye-wye (or delta-delta) transformers.
In Figure 2A, the coupling capacitor delivers a current () to the output node. Figure 2B shows a circuit electrically identical to Figure 2A using Miller's theorem. The coupling capacitor is replaced on the input side of the circuit by the Miller capacitance C M {\displaystyle C_{M}} , which draws the same current from the driver as the ...