In United States Pharmacopeia (USP) General Chapter <711> Dissolution, there are four dissolution apparatuses standardized and specified. [6] They are: USP Dissolution Apparatus 1 – Basket (37 °C ± 0.5 °C ) USP Dissolution Apparatus 2 – Paddle (37 °C ± 0.5 °C) USP Dissolution Apparatus 3 – Reciprocating Cylinder (37 °C ± 0.5 °C)
I propose that USP Dissolution Apparatus 2 be merged into Dissolution testing. I think that the content in the article can easily be explained in the context of Dissolution testing, and the article is of a reasonable size that the merging of will not cause any problems as far as article size or undue weight is concerned.
The solubility classification is based on a United States Pharmacopoeia (USP) aperture. The intestinal permeability classification is based on a comparison to the intravenous injection. All those factors are highly important because 85% of the most sold drugs in the United States and Europe are orally administered. [citation needed]
In pharmaceutics, sink condition is a term mostly related to the dissolution testing procedure.. It means using a sheer volume of solvent, usually about 5 to 10 times greater than the volume present in the saturated solution of the targeted chemical (often the API, and sometimes the excipients) contained in the dosage form being tested.
The USP is published in a combined volume with the National Formulary (a formulary) as the USP-NF. [2] If a drug ingredient or drug product has an applicable USP quality standard (in the form of a USP-NF monograph), it must conform in order to use the designation "USP" or "NF".
A Soxhlet extractor is a piece of laboratory apparatus [1] invented in 1879 by Franz von Soxhlet. [2] It was originally designed for the extraction of a lipid from a solid material. Typically, Soxhlet extraction is used when the desired compound has a limited solubility in a solvent, and the impurity is insoluble in that solvent. It allows for ...
A modern self-contained HPLC Schematic representation of an HPLC unit (1) solvent reservoirs, (2) solvent degasser, (3) gradient valve, (4) mixing vessel for delivery of the mobile phase, (5) high-pressure pump, (6) switching valve in "inject position", (6') switching valve in "load position", (7) sample injection loop, (8) pre-column (guard column), (9) analytical column, (10) detector (i.e ...
Standards for tablet properties are published in the various international pharmacopeias (USP/NF, EP, JP, etc.). The hardness of tablets is the principal measure of mechanical strength. Hardness is tested using a tablet hardness tester. The units for hardness have evolved since the 1930s but are commonly measured in kilograms per square centimetre.